2017
DOI: 10.1039/c6ra28626g
|View full text |Cite
|
Sign up to set email alerts
|

Development of small-volume, microfluidic chaotic mixers for future application in two-dimensional liquid chromatography

Abstract: We report a microfluidic chaotic micromixer with staggered herringbone grooves having a geometry optimized for fast mobile-phase modification at the interface of a two-dimensional liquid chromatography system.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
45
0
1

Year Published

2018
2018
2022
2022

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 29 publications
(47 citation statements)
references
References 35 publications
(53 reference statements)
1
45
0
1
Order By: Relevance
“…Micromixer devices were fabricated by micromolding polyIJdimethylsiloxane) (PDMS, Sylgard 184, Dow Corning, Midland, MI, USA) on SU-8 molds, according to a procedure we have described in earlier work. 31 The 300-μm-wide, 51.5mm-long channels contained 16 arrays of cycles of 12 herringbone-shaped grooves each, which greatly enhance mixing in this laminar-flow regime through chaotic advection. 30,31 The channels were 60 μm deep, and 50 μm deeper Table 1 Optimized composition of the artificial digestive juices, dissolved in ultrapure water (adapted from Walczak et al 27 in the groove regions for optimal mixing characteristics.…”
Section: Fabrication Of Devicesmentioning
confidence: 99%
See 3 more Smart Citations
“…Micromixer devices were fabricated by micromolding polyIJdimethylsiloxane) (PDMS, Sylgard 184, Dow Corning, Midland, MI, USA) on SU-8 molds, according to a procedure we have described in earlier work. 31 The 300-μm-wide, 51.5mm-long channels contained 16 arrays of cycles of 12 herringbone-shaped grooves each, which greatly enhance mixing in this laminar-flow regime through chaotic advection. 30,31 The channels were 60 μm deep, and 50 μm deeper Table 1 Optimized composition of the artificial digestive juices, dissolved in ultrapure water (adapted from Walczak et al 27 in the groove regions for optimal mixing characteristics.…”
Section: Fabrication Of Devicesmentioning
confidence: 99%
“…Each compartment was decoupled from the rest of the system and studied individually to study the enzyme kinetics of that compartment. Therefore, devices containing a single micromixer (two inlets, one outlet, as described by Ianovska et al 31 ) were used to demonstrate enzymatic function in the separate compartments. Two syringe pumps (Harvard Apparatus, Pump 11 Pico Plus Elite, Holliston, MA, USA) were used with glass syringes (250 μL, Kloehn, Whittier, CA, USA) or plastic syringes (1 mL, Braun, Melsungen, Germany), containing either the digestive juice or the solution containing the compound to be digested.…”
Section: Enzymatic Assaysgeneralmentioning
confidence: 99%
See 2 more Smart Citations
“…Нами предлагается использовать для этого данные, снимаемые со спектрального / спектрофотометрического детектора типа «Gilson Spectrochrom M». Капиллярный ввод, используемый большинством пользователей без перестройки тракта, по уровню потока совместим с микрофлюидными помпами и смесителями для хроматографии на чипе [ 43 ] (а также с соответствующими микрофлюидно-хроматографическими интерфейсами для совмещения микроэкстракции и жидкостной хроматографии [ 44 ]). Детекторы этой марки, преимущественно, без конструктивных изменений, широко использовались (с 1960-х гг.…”
Section: техникаunclassified