2016
DOI: 10.1080/13645706.2016.1193027
|View full text |Cite
|
Sign up to set email alerts
|

Development of scar-less laparoscopic hernia repair (TAPP-252) facilitated by new 2mm instruments

Abstract: The newly developed 2 mm devices showed sufficient performance and durability in TAPP-252. Further investigation is necessary to assess durability and long-term outcomes.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 14 publications
(6 citation statements)
references
References 10 publications
0
6
0
Order By: Relevance
“…However, since these studies have been conducted, there has been much advancement in laparoscopic surgery technology. For example, needle graspers have made it possible to minimize pain caused by abdominal penetration 10 . Mesh fixation has become controversial, and non‐fixation methods like fibrin glue have shown lower pain while not affecting recurrence rates 11‐13 .…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, since these studies have been conducted, there has been much advancement in laparoscopic surgery technology. For example, needle graspers have made it possible to minimize pain caused by abdominal penetration 10 . Mesh fixation has become controversial, and non‐fixation methods like fibrin glue have shown lower pain while not affecting recurrence rates 11‐13 .…”
Section: Discussionmentioning
confidence: 99%
“…For example, needle graspers have made it possible to minimize pain caused by abdominal penetration. 10 Mesh fixation has become controversial, and nonfixation methods like fibrin glue have shown lower pain while not affecting recurrence rates. [11][12][13] On the other hand, in open surgery, the use of light-weight meshes…”
Section: Discussionmentioning
confidence: 99%
“…A needle port (BJ port ® , Nition Company, Chiba, Japan) is punctured percutaneously and inserted into the stomach in the left subcostal margin, through which a variety of 2 mm instruments (electrode, grasper, scissors, etc.) (17) are brought in ( Figure 4A,B,C).…”
Section: Single Incision Peigsmentioning
confidence: 99%
“…We developed a series of 2 mm instruments in corporation with Niti-On Co., Ltd. (Chiba, Japan). These instruments are called BJ series including grasping forceps (BJ needle ® ), metal trocar and cannula (BJ port ® ), rigid endoscope with 30 degree oblique view (BJ scope ® ), monopolar electrocautery with a hook-shaped electrode (BJ hook ® ), scissors (BJ scissors ® ), and needle driver (BJ pico ® ) (17). These instruments are autoclavable.…”
Section: Needlescopic Peigsmentioning
confidence: 99%
“…Laparoscopic transabdominal preperitoneal hernia repair (TAPP) has been increasingly employed because it provides excellent clinical outcomes, and it is recommended by the hernia guideline . Recently, to minimize the invasiveness of TAPP, a trocar no larger than 5 mm was used instead of 12‐mm trocar to apply mesh . We previously reported the usefulness of the Tornado gauze procedure to introduce a large piece of gauze via a 5‐mm trocar .…”
Section: Introductionmentioning
confidence: 99%