1990
DOI: 10.1109/14.64502
|View full text |Cite
|
Sign up to set email alerts
|

Development of real-time system for simultaneous observation of visual discharges and leakage current on contaminated DC insulators

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

1999
1999
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 21 publications
(5 citation statements)
references
References 6 publications
0
5
0
Order By: Relevance
“…It was observed from literature that PD and LC values are effected by changing the configuration and testing conditions of nano composites. To understand the effective change in these values PD and LC can be correlated [26]. PD may exist in the region of strong electric field that ionizes the air and make it conductive.…”
Section: Efforts Done In Previous Studiesmentioning
confidence: 99%
“…It was observed from literature that PD and LC values are effected by changing the configuration and testing conditions of nano composites. To understand the effective change in these values PD and LC can be correlated [26]. PD may exist in the region of strong electric field that ionizes the air and make it conductive.…”
Section: Efforts Done In Previous Studiesmentioning
confidence: 99%
“…But in references [7][8] behavior of insulators is studied under conditions that their surface pollution is not uniform and electrical behavior of insulators and their critical parameters are modeled under such conditions. Besides above mentioned cases, there are a variety of methods in which detection of insulators conditions and prediction of flashover are suggested [9][10][11][12][13][14][15][16][17]. In most of these methods, study on leakage current of insulator and extraction of detection criterion of insulators' critical conditions out of their behavior changes are considered.…”
Section: Introductionmentioning
confidence: 99%
“…All of the above studies adopted the overall measurement method to study the wetting characteristics of a polluted layer in insulators based on leakage current or surface conductivity. However, the leakage-current-based method requires thousands of volts of test voltage [14][15][16]. In addition, the thermal effect of the leakage current may lead to uneven wetting of the polluted layer of the insulators and even to the phenomenon of a partial dry zone.…”
Section: Introductionmentioning
confidence: 99%