2008
DOI: 10.4271/2008-01-2002
|View full text |Cite
|
Sign up to set email alerts
|

Development of Passively Actuated Thermal Control Valves for Passive Control of Mechanically Pumped Single-Phase Fluid Loops for Space Applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2010
2010
2016
2016

Publication Types

Select...
4
2

Relationship

3
3

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 11 publications
0
6
0
Order By: Relevance
“…The MSL rover utilizes a mechanically pumped, single-phase fluid loop heat rejection system (HRS) to create the backbone for thermal control 8,9,10,11,12,13,14 . The fluid loop uses chlorofluorocarbon-11 (CFC-11) as the working fluid.…”
Section: Rover Thermal Architecturementioning
confidence: 99%
“…The MSL rover utilizes a mechanically pumped, single-phase fluid loop heat rejection system (HRS) to create the backbone for thermal control 8,9,10,11,12,13,14 . The fluid loop uses chlorofluorocarbon-11 (CFC-11) as the working fluid.…”
Section: Rover Thermal Architecturementioning
confidence: 99%
“…Papers describing the function of the Rover HRS in detail have been previously published. [1][2][3][4][5][6][7][8] Figures 7 and 8 are schematics showing the HRS system and its major components. In the cold case, the HRS pumps liquid Freon through tubes in hot plate heat exchangers, located on either side of the MMRTG, to pick up radiated waste heat from the MMRTG and bring it into the RAMP.…”
Section: B Brief Description Of Msl Rover Thermal Designmentioning
confidence: 99%
“…One reason for the repeatability of RAMP temperatures over the Mars diurnal is the performance of the passive mixer and splitter valves in the HRS system. 4 The mixer valve is responsible for determining the amount of flow in the hot plates and therefore the amount of heat addition into the HRS Freon fluid. At night, when the RAMP needs heat and the mixer valve goes below -10°C, the valve opens up to allow 97% of the flow to go through the hot plates.…”
Section: Mars Surface Flight Performance Of Hrs and Internal Elementioning
confidence: 99%
“…Compared to numerical methods, this approach is proposed to be more authentic for [14,15]. J. Liu et al investigated the start-up processes of mechanically pumped cooling loop and the start-up processes of the evaporator heat sink in a Walk-in Climate Chamber [16].…”
Section: Introductionmentioning
confidence: 99%