Eighth IEE International Conference on Developments in Power System Protection 2004
DOI: 10.1049/cp:20040072
|View full text |Cite
|
Sign up to set email alerts
|

Development of non-communication relays for transmission and distribution systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
3
0

Year Published

2006
2006
2015
2015

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…Current differential protection has been playing an important role in transmission line protection [3,4]. The longitudinal current differential protections use the differential current between both ends of the lines and need a communication link [5][6][7][8]. The conventional cross-differential relay is based on the comparison between the current amplitudes of two parallel lines, and it identifies an internal fault when the difference between the two currents exceeds a certain threshold.…”
Section: Introductionmentioning
confidence: 99%
“…Current differential protection has been playing an important role in transmission line protection [3,4]. The longitudinal current differential protections use the differential current between both ends of the lines and need a communication link [5][6][7][8]. The conventional cross-differential relay is based on the comparison between the current amplitudes of two parallel lines, and it identifies an internal fault when the difference between the two currents exceeds a certain threshold.…”
Section: Introductionmentioning
confidence: 99%
“…The dramatic growth in signal processing power of relay platforms, and the availability of suitable communication schemes have provided a new opportunity to revisit the concept of integrated protection. Research shows that information obtained from multiple power plants and components can be used to derive new protection principles and schemes, which could have significant advantages over the existing protection techniques based on individual plant or component [11][12][13][14][15][16][17][18][19][20][21][22][23] when supported by modern communication technology [24] . This paper presents an integrated relay and its associated protection scheme based on the combination of a number of protection algorithms.…”
mentioning
confidence: 99%
“…At the same time, the dramatic growth in signal processing power of relay platforms, and the availability of suitable communications schemes, has provided a new opportunity to develop new protection techniques. Research shows that information obtained from multiple power plants and components can be used to derive new protection principles and schemes, which could have significant advantages over the existing protection techniques based on individual plant or component [15][16][17][18][19][20][21][22][23][24][25][26][27]. Recently, a novel integrated protection scheme based on fault transient detection is proposed [28].…”
mentioning
confidence: 99%