2019
DOI: 10.1080/24699322.2019.1649070
|View full text |Cite
|
Sign up to set email alerts
|

Development of modified RSA algorithm using fixed mersenne prime numbers for medical ultrasound imaging instrumentation

Abstract: Purpose: Encryption of patient information has become an important issue in medical ultrasound instrumentation to secure information when images are accessed off-site. The proposed algorithm is used to encrypt private medical images and transfer the encrypted images to improve the encryption capability and elapsed time. Materials and methods: We generate a public key using three prime numbers, including a fixed Mersenne prime number, in the modified Rivest-Shamir-Adelman (RSA) algorithm to compare the encrypti… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6
2
1

Relationship

2
7

Authors

Journals

citations
Cited by 10 publications
(6 citation statements)
references
References 19 publications
0
6
0
Order By: Relevance
“…In the RSA encryption systems, it might be possible to create a public key such as the product of two large prime numbers, p and q. 64 The encoding value may be large, c. Since the prime numbers are kept secret, most observers will be able to encrypt a message but only an operator who knows the primes will be able to decrypt it.…”
Section: Rivest-shamir-adleman Encryptionmentioning
confidence: 99%
“…In the RSA encryption systems, it might be possible to create a public key such as the product of two large prime numbers, p and q. 64 The encoding value may be large, c. Since the prime numbers are kept secret, most observers will be able to encrypt a message but only an operator who knows the primes will be able to decrypt it.…”
Section: Rivest-shamir-adleman Encryptionmentioning
confidence: 99%
“…This article employs Hamming error correction and detection. Shin et al [79] used the encryption and transportation of confidential medical images to enhance encryption capability and elapsed time. When compared to methods that employ two prime numbers Huang et al [80] presented a novel asymmetric pixel confusion method for images in 2020, which was based on the Rivest-Shamir-Adleman (RSA) public-key cryptosystem and the Arnold map.…”
Section: Imagementioning
confidence: 99%
“…Among medical systems, ultrasound instruments are widely used in ambulances [1][2][3][4][5]. Compared to bench-top ultrasound instruments, which have a 100-240 V alternating current (AC) cord, other ultrasound instruments have a limited power supply [6,7].…”
Section: Introductionmentioning
confidence: 99%