2016
DOI: 10.1134/s1062739116020477
|View full text |Cite
|
Sign up to set email alerts
|

Development of method to improve efficiency of residual current device under 1000 V on excavators of mining enterprises

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 2 publications
0
4
0
Order By: Relevance
“…According to the change in the value of the random relative root‐mean‐square error from the connected conductance value, the conductance value is determined to ensure sufficient accuracy in determining the insulation parameters of the electrical network, taking into account the achievement of measuring safety for the values of voltage modules. It is also essential that the selected additional conductance does not violate the operating mode of electrical receivers and does not negatively affect the reliability of the elements in the internal power supply system during the work performance in electrical installations to determine the insulation parameters [7].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…According to the change in the value of the random relative root‐mean‐square error from the connected conductance value, the conductance value is determined to ensure sufficient accuracy in determining the insulation parameters of the electrical network, taking into account the achievement of measuring safety for the values of voltage modules. It is also essential that the selected additional conductance does not violate the operating mode of electrical receivers and does not negatively affect the reliability of the elements in the internal power supply system during the work performance in electrical installations to determine the insulation parameters [7].…”
Section: Discussionmentioning
confidence: 99%
“…The analysis of the root‐mean‐square error of Equations (9), (10) with indirect measurements is shown in the thesis [6, 7], where «the minimum random relative root‐mean‐square error will be at UA1=0,5UN0.28em${U_{A1}} = 0,5{U_N}\;$. When using a measuring voltage transformer, voltmeters with an accuracy class of 0,5, the random relative root‐mean‐square error in determining the conductance and susceptance of the electrical network insulation does not exceed 5% with the variation range of the phase‐to‐earth voltage modulus within limits UA1=(0,30,75)UN0.28em${U_{A1}} = ( {0,3 - 0,75} ){U_N}\;$».…”
Section: The Theoretical Basismentioning
confidence: 99%
“…Czaja analyzed RCDs with different designed release systems and illustrated their effects on release frequency range [9]. Utegulov et al have developed a method to increase the efficiency of RCDs below 1000 volts based on direct installation [10]. Porta et al performed a study on faulty switches of RCDs in circuits feeding electronic loads [11].…”
Section: Introductionmentioning
confidence: 99%
“…Studies on the condition of insulations in the development of coal deposits and mining open pits in short networks up to 1000 V on excavators are not sufficient to be produced. Installed residual current devices in short networks up to 1000 V excavators have not been studied in relation to the criteria for electric normal and emergency operating modes [17].…”
Section: Introductionmentioning
confidence: 99%