2023
DOI: 10.1016/j.foodchem.2022.135012
|View full text |Cite
|
Sign up to set email alerts
|

Development of matrix certified reference material for accurate determination of docosahexaenoic acid in milk powder

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 15 publications
0
5
0
Order By: Relevance
“… where s 1 represents the between-bottle variance, s 2 represents the within-bottle variance, and n is 3. Additionally, the target measurement uncertainty of the CRM ( u trg ) was expected to be around 3.0 μg/kg . The samples showed a negligible contribution to the uncertainty of the certified value because the s r was smaller than , Therefore, the results confirmed that the CRMs were homogeneous for AFB 1 at the 95% confidence level, with the minimum sampling amount for the CRM of 1.0 g.…”
Section: Resultsmentioning
confidence: 65%
See 3 more Smart Citations
“… where s 1 represents the between-bottle variance, s 2 represents the within-bottle variance, and n is 3. Additionally, the target measurement uncertainty of the CRM ( u trg ) was expected to be around 3.0 μg/kg . The samples showed a negligible contribution to the uncertainty of the certified value because the s r was smaller than , Therefore, the results confirmed that the CRMs were homogeneous for AFB 1 at the 95% confidence level, with the minimum sampling amount for the CRM of 1.0 g.…”
Section: Resultsmentioning
confidence: 65%
“…As mentioned above, in the case of homogeneity, both s bb and s r were utilized to evaluate the homogeneity of the CRM samples. Because the value of s r was larger than that of s bb , the s r was adopted as the component of uncertainty ( u bb ). , It could be found that these AFB 1 CRM samples were homogeneous with an uncertainty level of 0.40 μg/kg (Table ). Moreover, the uncertainty of stability included the uncertainty of short-term stability ( u sts ) and the uncertainty of long-term stability ( u lts ).…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The measurement results were linearly fitted to show the stability trend, and regression analysis statistical tests were performed on the data. According to ISO guideline 35:2007 [38], the t test was used to calculate the significance of the slope a, where s(a) is the uncertainty of the slope a, as calculated using Equations ( 5) and (6).…”
Section: Parameters Valuesmentioning
confidence: 99%