2016
DOI: 10.1016/j.radmeas.2015.12.006
|View full text |Cite
|
Sign up to set email alerts
|

Development of human hand phantom containing radiophotoluminescence material

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(4 citation statements)
references
References 18 publications
0
4
0
Order By: Relevance
“…The research on the preparation and evaluation of the gloves sandwiched in the bead-type glass dosimeter between acrylic binders on an organic film is currently in progress. (10) …”
Section: Methodsmentioning
confidence: 99%
“…The research on the preparation and evaluation of the gloves sandwiched in the bead-type glass dosimeter between acrylic binders on an organic film is currently in progress. (10) …”
Section: Methodsmentioning
confidence: 99%
“…为了更好地研究人体四肢的剂量监测,研究人 员通过制备肢体模型以预评估在诊断放射学和放射 治疗的临床过程中可接受的剂量。从生物等效性的 角度研究,当剂量计所用材料的 Zeff 接近人体软组 织时,可以省去对能量依赖性的数学校准,因此在 进行人体剂量监测(特别是辐射防护)时,通常使用 轻元素组成的材料。基于此,Sato 等 [86] 使用聚氨酯 树脂、银活化偏磷酸盐玻璃颗粒和空心玻璃微球制 备了一种密度为 1.1 g/cm 3 且具有高辐射敏感性的 RPL 材料。该材料在 10 mGy~6×10 4 6 RPL materials for radiation dosimetry (a) Fluorescence attenuation curve (top) and novel readout technique using pulsed ultraviolet laser (bottom) [7] ; (b) Internal images of RPLGD [7] ; (c) Comparison of RPL response signals irradiated by different metal filters and different types of radiation (X, γ and β-rays) [7] ; (d) Spherical RPLGD prepared by melting method [82] ; (e) Spherical RPLGD used to monitor radioactive contaminants in harsh environments [83] ; (f) 2D dose distribution of each layer at different depths of the hand model soaked in polyester resin block (left) and 3D dose distribution of the complete structure of the hand model after X-ray irradiation [86] ; (g) Contrast enhanced image of RPL photograph after digital image processing. The inset shows RPL glass particles covered with polystyrene plate placed in a petri dish.…”
Section: D 模型用于人体的剂量监测mentioning
confidence: 99%
“…The number of components was found to be two because the formation of two defects, namely Ag 2 + and Ag 2+ , may be responsible for the build-up process. 27) The temperature dependence of the build-up parameter t j was obtained by fitting the temperature dependence of the build-up process using Eq. (8).…”
Section: -5mentioning
confidence: 99%
“…Recently, many researchers have reported new applications of Ag-doped phosphate glasses, such as RPL dosimeters with various shapes [27][28][29] as well as real-time 30) and high-temperature-resistant RPL dosimeters. 31) However, real-time RPL dosimetry is difficult because of the build-up effect, which involves the formation of RPL centers over time.…”
Section: Introductionmentioning
confidence: 99%