2018
DOI: 10.1016/j.talanta.2017.09.037
|View full text |Cite
|
Sign up to set email alerts
|

Development of flow systems incorporating membraneless vaporization units and flow-through contactless conductivity detector for determination of dissolved ammonium and sulfide in canal water

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
13
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 31 publications
(14 citation statements)
references
References 26 publications
1
13
0
Order By: Relevance
“…For comparative purposes, the performance characteristics of the proposed method and other selected on-line separation methods based on gas diffusion, pervaporation, membranelles-GD, and HS-SD devises, reported in the literature for ammonium determination, are compiled in Table 1. As it is shown herein, the P&T-SIA method reveals satisfactory sensitivity with better detection limits than earlier works [10,12,[15][16][17][29][30][31] for ammonium assays. In addition, it should be considered that the proposed system overcomes membrane-related problems and allows for the determination of untreated samples, minimizing the cost of analysis.…”
Section: Figures Of Meritsupporting
confidence: 50%
“…For comparative purposes, the performance characteristics of the proposed method and other selected on-line separation methods based on gas diffusion, pervaporation, membranelles-GD, and HS-SD devises, reported in the literature for ammonium determination, are compiled in Table 1. As it is shown herein, the P&T-SIA method reveals satisfactory sensitivity with better detection limits than earlier works [10,12,[15][16][17][29][30][31] for ammonium assays. In addition, it should be considered that the proposed system overcomes membrane-related problems and allows for the determination of untreated samples, minimizing the cost of analysis.…”
Section: Figures Of Meritsupporting
confidence: 50%
“…The C4D detection flow cell [23,24,26] is a polyether ether ketone (PEEK) tubing (1.0 mm i.d., 1.6 mm o.d.) with two cylindrical bands of painted silver conductive ink (2.0 cm long and 0.5 mm apart) as electrodes.…”
Section: Flow Systems and Operationmentioning
confidence: 99%
“…C4D has advantages over conventional conductivity detector for flow systems since the electrodes are easily mounted on the outer wall of the flow tube and is robust in use. Several applications of MBL-VP-C4D for the analysis of volatile gases converted from ionic analytes have been presented, such as dissolved ammonium and sulfide in canal water [23] and sulfite in wines [24].…”
Section: Introductionmentioning
confidence: 99%
“…Carbon dioxide was diffused from an acidified seawater sample across a semipermeable membrane into an acceptor stream (aqueous alkaline solution) and changes in conductivity, which were directly related to CO 2 content in the sample, were monitored by C 4 D . Similarly, C 4 D was also employed in sequential injection analysis (SIA) for the determination of sulfite in wines and of ammonium and sulfide in canal water . In these cases, separations of the analytes were carried out in membraneless gas diffusion cells.…”
Section: Other Applications Of C4dmentioning
confidence: 99%