2020
DOI: 10.1016/j.chroma.2020.461039
|View full text |Cite
|
Sign up to set email alerts
|

Development of efficient on-bead protein elution process coupled to ultra-high performance liquid chromatography–tandem mass spectrometry to determine immunoglobulin G subclass and glycosylation for discovery of bio-signatures in pancreatic disease

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
11
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 10 publications
(12 citation statements)
references
References 32 publications
1
11
0
Order By: Relevance
“…In those studies, LC coupled with MS was usually the main analytical tool. In our previous work, we also developed and validated a UHPLC-MS/MS method to achieve absolute quantification of the four IgG subclasses, and relative quantification of 26 IgG glycopeptides, from plasma samples [ 18 ]. In this study, we applied the same workflow, to which a stable isotope-labeled IgG internal standard was added to each sample.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…In those studies, LC coupled with MS was usually the main analytical tool. In our previous work, we also developed and validated a UHPLC-MS/MS method to achieve absolute quantification of the four IgG subclasses, and relative quantification of 26 IgG glycopeptides, from plasma samples [ 18 ]. In this study, we applied the same workflow, to which a stable isotope-labeled IgG internal standard was added to each sample.…”
Section: Resultsmentioning
confidence: 99%
“…Sample preparation and analytical conditions were previously developed and validated by our team [ 18 ]. Briefly, 60 μL of magnetic bead slurry immobilized with protein G was used for IgG purification.…”
Section: Methodsmentioning
confidence: 99%
“…These studies have investigated glycation of human serum albumin (HSA) as markers for diabetes to complement HbA1c (Korwar et al, 2015). Glycosylation of immunoglobulin G (IgG), the most abundant antibody in serum, has further been investigated as a source of markers for pancreatic cancer and pancreatitis (Chen et al, 2014;Shih et al, 2019;Shiao et al, 2020). The focus on IgG is also consistent with the immune facets of both pancreatic cancer and T1D.…”
Section: Clinical Utility Considerationsmentioning
confidence: 99%
“…For multiple reaction monitoring assays requiring high sensitivity and quantitative accuracy, triple quadrupole instruments have become a common feature of clinical laboratories (Shiao et al, 2020). Instruments with other mass analyzers can perform the similarly named parallel reaction monitoring which can also enable fast and sensitive quantification.…”
Section: Clinical Utility Considerationsmentioning
confidence: 99%
See 1 more Smart Citation