2018
DOI: 10.1016/j.talanta.2018.04.049
|View full text |Cite
|
Sign up to set email alerts
|

Development of dried serum spot sampling techniques for the assessment of trace elements in serum samples by LA-ICP-MS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
8
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 18 publications
(10 citation statements)
references
References 26 publications
1
8
0
Order By: Relevance
“…Moreda‐Piñeiro et al reported iodine determination in DBS using matrix‐matched calibration by LA‐ICP‐MS . Chantada‐Vázquez et al analyzed the trace elements in DBS using matrix‐matched calibration by LA‐ICP‐MS …”
Section: Introductionmentioning
confidence: 73%
See 2 more Smart Citations
“…Moreda‐Piñeiro et al reported iodine determination in DBS using matrix‐matched calibration by LA‐ICP‐MS . Chantada‐Vázquez et al analyzed the trace elements in DBS using matrix‐matched calibration by LA‐ICP‐MS …”
Section: Introductionmentioning
confidence: 73%
“…The basic concept of dried‐droplet LA consists of depositing a well‐defined volume of liquid sample on a solid support, evaporating the solvent, and examining the remaining dried residue by means of laser ablation coupled with inductively coupled plasma mass spectrometry (LA‐ICP‐MS) . LA‐ICP‐MS is commonly used for analyzing precious natural specimens and has been applied successfully to the determination of geological and biological samples . However, the lack of a series of appropriate certified reference materials (CRMs) with the same or similar matrix composition limits the applicability of this approach.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Direct biofluid analysis by LA-ICP-MS is also a topic being continuously explored. A recent approach for serum analysis by LA-ICP-MS using dried serum spot (DSS) sampling, using only 20 μL of serum, was proposed by Chantada-Vázquez et al [9]. Direct multi-element determination (Al, Be, Ca, Cu, Fe, K, Li, Mg, Mn, Mo, Na, P, Rb, Se, V, and Zn) in DSS sampled in filter paper discs with 2.7 mm diameter and employing acetic acid as an oxidizing agent (used to remove organic matter from the biological matrix) was achieved at low limits of detection levels.…”
Section: Developments In La-icp-ms For Bioanalysismentioning
confidence: 99%
“…Other laboratories used LA-ICP-MSI or related techniques to analyze the composition of human kidney stones [54], identify inflammatory hotspots associated with elevated metal quantities in placental tissue from low-birth-weight pregnancy [55], map trace and bulk elements in tumor tissue obtained from an individual previously treated with cisplatin [56], and define contaminations in human hair or teeth resulting from occupational exposure or unfavorable dental fillings [57][58][59]. Likewise, the first studies analyzed element distribution in human eye lenses, brain tissue, or skin biopsies from patients suffering from renal insufficiency [60][61][62], optimized radiodosages in treatment of tumors [63], or determined individual metals or metal-containing contrast agents in human blood or serum [64][65][66][67][68]. In addition, there are many inborn errors of metal and metalloid metabolism human trace elements disorders, in which LA-ICP-MSI offers advantages.…”
Section: Translational Aspects Of La-icp-msimentioning
confidence: 99%