2020
DOI: 10.24295/cpsstpea.2020.00013
|View full text |Cite
|
Sign up to set email alerts
|

Development of Cascaded Multilevel Inverter Based Active Power Filter With Reduced Transformers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
26
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 55 publications
(27 citation statements)
references
References 0 publications
1
26
0
Order By: Relevance
“…To evaluate the proposed method efficiency, Table 4 shows a performance comparison between the proposed strategy and other strategies recently adopted for APF control [16,17,20,[36][37][38][39]. This comparison was based on inverter flying capacitor voltage ripple rate ΔVc% under ideal and non-ideal grid voltages after SAPF connection, transient regime capacitor voltages overshoot and undershoot and maximal ΔVc%, transient response time Δtset for capacitor voltage rebalancing to reach their references, grid problem number for which robustness has been tested and based on cost and complexity in terms of devices used such as regulators, sensors, and measuring instruments.…”
Section: Comparison Of Control Strategies Performance For Apfmentioning
confidence: 99%
See 1 more Smart Citation
“…To evaluate the proposed method efficiency, Table 4 shows a performance comparison between the proposed strategy and other strategies recently adopted for APF control [16,17,20,[36][37][38][39]. This comparison was based on inverter flying capacitor voltage ripple rate ΔVc% under ideal and non-ideal grid voltages after SAPF connection, transient regime capacitor voltages overshoot and undershoot and maximal ΔVc%, transient response time Δtset for capacitor voltage rebalancing to reach their references, grid problem number for which robustness has been tested and based on cost and complexity in terms of devices used such as regulators, sensors, and measuring instruments.…”
Section: Comparison Of Control Strategies Performance For Apfmentioning
confidence: 99%
“…Considering MLI-based A.P.F, where the number of parameters to be controlled is very important, adaptive PI control seems to be unable to control. The development of cascaded MLI-based APF with reduced transformers is proposed in [20], this method is not enough accurate. Furthermore, the inverter output voltage is poor, the transient regime time and overshoot at disturbance instant are important.…”
Section: Introductionmentioning
confidence: 99%
“…Since SAPF is used for compensating load harmonic currents, it is common to simplify the load into a harmonic current source in the modeling of SAPF [13][14][15][16]. Research effort has been mainly put on current control strategies [17][18][19][20][21][22], topologies [23][24][25], and reference current extraction methods [26][27][28] to enhance the harmonic compensation performance. It takes for granted to consider SAPF to be in favor of system stability by eliminating harmonic currents.…”
Section: Introductionmentioning
confidence: 99%
“…Cascaded H-bridge 5-level inverter incorporated by means of a PID controller is established for controlling the capacitor potential with reduction in the size; cost and weight are achieved in [19]. Cascaded multi-level inverter, which regulates the quality of power delivered with minimized cost and space, is presented [20].…”
Section: Introductionmentioning
confidence: 99%