Development of Antigen Detection Assay for Diagnosis of Tuberculosis Using Sputum Samples

Abstract: The rising incidence of tuberculosis worldwide means an increasing burden on diagnostic facilities, so tests simpler than Ziehl-Neelsen staining are needed. Such tests should be objective, reproducible, and have at least as good a detection limit as 10 4 bacteria/ml. A capture enzyme-linked immunosorbent assay (ELISA) was developed for detection of lipoarabinomannan (LAM) in human sputum samples. As a capture antibody, we used a murine monoclonal antibody against LAM, with rabbit antiserum against Mycobacteriu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
16
0

Year Published

2006
2006
2019
2019

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(17 citation statements)
references
References 12 publications
(21 reference statements)
1
16
0
Order By: Relevance
“…Mechanical biosensors in attenuated Mtb cells achieved LOD of 2 × 10 3 (He et al, 2003) and 10 5 (He and Zhang, 2002), respectively, with acoustic wave and quartz crystal microbalance. In optical biochips, LOD was 10 3 and 10 4 cells/mL with Mtb sputum samples, respectively, when using isothermal loop mediated amplification (Creecy et al, 2015) and capture ELISA of lipoarabinomannan antigen (Arias-Bouda et al, 2000). Similar LOD results, 10 3 and 10 4 , were achieved by magnetic methods, respectively, by using a magnetic barcode in sputum (Liong et al, 2013) and a magnetoelastic biosensor in Mtb H37Ra strain cells (Pang et al, 2008).…”
Section: Benchmark With the State-of-the-artmentioning
confidence: 68%
See 2 more Smart Citations
“…Mechanical biosensors in attenuated Mtb cells achieved LOD of 2 × 10 3 (He et al, 2003) and 10 5 (He and Zhang, 2002), respectively, with acoustic wave and quartz crystal microbalance. In optical biochips, LOD was 10 3 and 10 4 cells/mL with Mtb sputum samples, respectively, when using isothermal loop mediated amplification (Creecy et al, 2015) and capture ELISA of lipoarabinomannan antigen (Arias-Bouda et al, 2000). Similar LOD results, 10 3 and 10 4 , were achieved by magnetic methods, respectively, by using a magnetic barcode in sputum (Liong et al, 2013) and a magnetoelastic biosensor in Mtb H37Ra strain cells (Pang et al, 2008).…”
Section: Benchmark With the State-of-the-artmentioning
confidence: 68%
“…In these settings, direct Ziehl-Neelsen (ZN) sputum smear microscopy is an important diagnostic technique, although the method is laborious and prone to human error and to infection exposure (Yeo et al, 2009;Matu and Juma, 2013;Creecy et al, 2015). ZN only identifies TB pulmonary cases in sputum samples, with a limit of detection (LOD) of 10 4 cells/mL (Arias-Bouda et al, 2000;Yeo et al, 2009;Creecy et al, 2015). Therefore, active TB cases with lower number of cells, patients with negative sputum results, children, HIV patients and extrapulmonary TB, need a different diagnostic approach (Moreno-Pérez et al, 2010;Parsons et al, 2011;Veigas et al, 2012;WHO, 2012).…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…This process will cause damage to the cells of M.tuberculosis, so many proteins will be secreted. 8,18 In addition, the reading results of TB Ag Rapid Test Device using routine procedures (Tube 1) were 43.3% for the positive one and 56.7% for the negative one. The low results were possibly caused by Ag of M.tuberculosis still trapped in the viscous mucous.…”
Section: Resultsmentioning
confidence: 97%
“…In addition to these approaches, efforts are also underway to develop immune-based assays that focus on antigen rather than antibody detection. For example, antigen-capture enzymelinked immunosorbent assays for the detection of lipoarabinomannan in sputum [23] and urine [24] samples have demonstrated promise in early trials. Further work is necessary to determine their utility.…”
Section: Immunological Tests Including Serological Assaysmentioning
confidence: 99%