Development of an MRI-Compatible Device for Prostate Focal Therapy

Abstract: We present a device that has been developed for delivering prostate focal thermal therapy under magnetic resonance imaging (MRI) guidance. Unlike most existing devices, ours is capable of delivering needles to targets in the prostate without removing the patient from the scanner. This feature greatly reduces procedure time and increases accuracy. The device consists of a mechanical linkage encoded with optical incremental encoders, and is manually actuated. A custom magnetic resonance (MR) compatible alignment… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
5
1

Relationship

3
3

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 11 publications
0
8
0
Order By: Relevance
“…Preliminary results from this work have been previously described in a conference paper. 35 In this previous publication, the trajectory alignment device was briefly described and only one simple test of needle guidance accuracy was performed. This paper includes rigorous testing of needle guidance accuracy and repeatability using a more realistic prostate phantom, demonstration of a user interface that is integrated with the MRI scanner and trajectory alignment device, and results from initial experiences using the system to deliver focal laser ablation therapy to two patients.…”
Section: Introductionmentioning
confidence: 99%
“…Preliminary results from this work have been previously described in a conference paper. 35 In this previous publication, the trajectory alignment device was briefly described and only one simple test of needle guidance accuracy was performed. This paper includes rigorous testing of needle guidance accuracy and repeatability using a more realistic prostate phantom, demonstration of a user interface that is integrated with the MRI scanner and trajectory alignment device, and results from initial experiences using the system to deliver focal laser ablation therapy to two patients.…”
Section: Introductionmentioning
confidence: 99%
“…Much of this increased time is from repeatedly moving the patient out of the scanner to enable access to the needle, followed by repeat imaging. Some investigators have therefore looked at MR compatible robotic devices via rectal [32], gluteal [33] and perineal approaches [ 35,36] recently described an MR compatible mechatronic system for transperineal needle guidance ( Fig. 1).…”
Section: In-bore Prostate Biopsymentioning
confidence: 99%
“…Cepek et al 59 at Robarts Research Institute presented a device for delivering prostate focal thermal therapy under MRI guidance shown in Fig. 14(a).…”
Section: Robots For Transrectal Prostate Interventionsmentioning
confidence: 99%