2019
DOI: 10.1016/j.ejmp.2019.07.002
|View full text |Cite
|
Sign up to set email alerts
|

Development of an IAEA phase-space dataset for the Leksell Gamma Knife® Perfexion™ using multi-threaded Geant4 simulations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
12
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 11 publications
(13 citation statements)
references
References 23 publications
0
12
0
Order By: Relevance
“…The Penelope low‐energy electromagnetic physics model was employed, and the secondary particle production cut value was 990 eV, which was the minimum energy value in the physics list. The simulation was verified using dose distributions measured with films 22 . The absorbed doses to water in the CV, a 0.5 × 0.5 × 0.5 mm 3 cube, and the ISSs in water spheres with radii of 8 cm were obtained using simulations (Figure 5a,b).…”
Section: Methodsmentioning
confidence: 90%
See 1 more Smart Citation
“…The Penelope low‐energy electromagnetic physics model was employed, and the secondary particle production cut value was 990 eV, which was the minimum energy value in the physics list. The simulation was verified using dose distributions measured with films 22 . The absorbed doses to water in the CV, a 0.5 × 0.5 × 0.5 mm 3 cube, and the ISSs in water spheres with radii of 8 cm were obtained using simulations (Figure 5a,b).…”
Section: Methodsmentioning
confidence: 90%
“…The correction factors were also obtained with MC simulation codes developed in-house. 22 Eight simulations with 1.92 × 10 10 primary photons were performed for each collimator. The simulated volume averaging correction factor ratios and the LGP values were within 0.3% of each other.…”
Section: Correction Factor Ratiosmentioning
confidence: 99%
“…Figure 2 shows the overlapping particle positions sampled from all 24 GK phase spaces manifesting three collimator sizes (color coded by red for 16 mm, green for 8 mm, and blue for 4 mm), eight sectors (at different azimuth angles), and five rings (at different zenith angles). Note that the display in Figure 2 is on the phase spaces, not the real source distribution, which is on a conical surface for GK Perfexion/Icon 11–13 . Also note that since the current GK treatment planning and delivery can only be modulated at the level of sectors, not at the level of rings or individual sources, we do not need to record the phase space for each source or ring for the purpose of calculating reference kernels.…”
Section: Methodsmentioning
confidence: 99%
“…The 60 Co ra dio ac tive iso tope-based irradiator is widely used in med i cal sci ence, ra di a tion mea surement, radionuclide anal y sis, in dus try ap pli ca tions, bio log i cal ex per i ments, and stan dard ir ra di a tion [1][2][3][4][5][6][7]. Dongnam In sti tute of Ra dio log i cal and Med i cal Sciences (DIRAMS) has a 60 Co irradiator (Gammabeam X-200, BEST Theratronics) for re search pur poses.…”
Section: Introductionmentioning
confidence: 99%