Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
2022
DOI: 10.3390/s22030833
|View full text |Cite
|
Sign up to set email alerts
|

Development of an Efficient Voltammetric Sensor for the Monitoring of 4-Aminophenol Based on Flexible Laser Induced Graphene Electrodes Modified with MWCNT-PANI

Abstract: Sensitive electrodes are of a great importance for the realization of highly performant electrochemical sensors for field application. In the present work, a laser-induced carbon (LIC) electrode is proposed for 4-Aminophenol (4-AP) electrochemical sensors. The electrode is patterned on a commercial low-cost polyimide (Kapton) sheet and functionalized with a multi-walled carbon nanotubes polyaniline (MWCNT-PANI) composite, realized by an in-situ-polymerization in an acidic medium. The LIC electrode modified wit… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2022
2022
2025
2025

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 18 publications
(6 citation statements)
references
References 62 publications
(72 reference statements)
0
6
0
Order By: Relevance
“… electrode method dynamic range (µM) detection limit (µM) ref. LIGE on PKI SWV 50–600 14.3 this work AuNPs-LIGE on PKI SWV 5–50 1.1 this work LSGE on PI SWV 0.1–10.0 0.004 [ 25 ] LIGE on PI SWV 0.1–0.01 0.031 [ 26 ] LIGE on PEI SWV 0.0–50 0.323 [ 27 ] MWCNTs/PANI/LIGE on PI SWV 0.1–55 0.006 [ 28 ] MWCNTs/PAMAM/GCE DPV 0.3–200 0.1 [ 48 ] MWCNTs/pGly/GCE DPV 0.5–100 1.7 [ 49 ] RuO 2 /Nafion/GCE SWV 5–250 1.2 [ 50 ] NanoMIPs/SPCE DPV 100–1000 50 ...…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“… electrode method dynamic range (µM) detection limit (µM) ref. LIGE on PKI SWV 50–600 14.3 this work AuNPs-LIGE on PKI SWV 5–50 1.1 this work LSGE on PI SWV 0.1–10.0 0.004 [ 25 ] LIGE on PI SWV 0.1–0.01 0.031 [ 26 ] LIGE on PEI SWV 0.0–50 0.323 [ 27 ] MWCNTs/PANI/LIGE on PI SWV 0.1–55 0.006 [ 28 ] MWCNTs/PAMAM/GCE DPV 0.3–200 0.1 [ 48 ] MWCNTs/pGly/GCE DPV 0.5–100 1.7 [ 49 ] RuO 2 /Nafion/GCE SWV 5–250 1.2 [ 50 ] NanoMIPs/SPCE DPV 100–1000 50 ...…”
Section: Resultsmentioning
confidence: 99%
“…Kavai et al fabricated LIG on the surface of PEI to simultaneously detect hydroquinone, PCM and methylparaben [ 27 ]. Nasraoui et al modified LIG with multi-walled carbon nanotubes (MWCNTs) and conductive polyaniline (PANI) polymer for sensitive sensing of PCM [ 28 ].…”
Section: Introductionmentioning
confidence: 99%
“…Biosensors are devices that convert biochemical/biological reactions into physicochemical signals for analysis, enabling quantitative assessment of analyte concentrations 68 . Biosensors can detect chemicals regarding food safety 111 , environmental chemical hazards 112 , and disease 113 .…”
Section: Biosensorsmentioning
confidence: 99%
“…For the analytical detection of diclofenac, the square-wave voltammetry (SWV) method was used due to its high sensitivity, enhanced peak resolution, and ability to discriminate the capacitive current [47] or to have low background current [48]. Figure 5A presents, as an example, the voltammograms recorded at the Chit + TiO 2 + 4HIS/GCE-modified electrode, and the calibration curves for all modified electrodes are presented in Figure 5B.…”
Section: Analytical Characterizationmentioning
confidence: 99%