2015
DOI: 10.1016/j.chroma.2015.09.082
|View full text |Cite
|
Sign up to set email alerts
|

Development of an analytical method for the determination of polyphenolic compounds in vegetable origin samples by liquid chromatography and pulsed amperometric detection at a glassy carbon electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
9
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 21 publications
(10 citation statements)
references
References 36 publications
0
9
0
Order By: Relevance
“…Foodstuff and plant extracts containing phenolic compounds including lignans have been electrochemically oxidized during the determination of the phenolic content [184,185,186,187] and the antioxidant capacity [188,189]. The drug etoposide, which is a semisynthetic epipodophyllotoxin glycoside, has been oxidized electrochemically using a carbon paste working electrode, a Ag/AgCl/3 M KCl reference electrode, and a platinum wire counter electrode, with a supporting electrolyte of varying pH.…”
Section: Other Oxidation Methodsmentioning
confidence: 99%
“…Foodstuff and plant extracts containing phenolic compounds including lignans have been electrochemically oxidized during the determination of the phenolic content [184,185,186,187] and the antioxidant capacity [188,189]. The drug etoposide, which is a semisynthetic epipodophyllotoxin glycoside, has been oxidized electrochemically using a carbon paste working electrode, a Ag/AgCl/3 M KCl reference electrode, and a platinum wire counter electrode, with a supporting electrolyte of varying pH.…”
Section: Other Oxidation Methodsmentioning
confidence: 99%
“…They are very reactive and causes a number of health complications. Antioxidants have the potential to scavenge them and maintain health [5–7].…”
Section: Introductionmentioning
confidence: 99%
“…A novel procedure for the determination of chlorogenic acid is of great interest for scientific and therapeutic reasons. Several methods were reported for the determination of chlorogenic acid including, liquid chromatography [2], high performance liquid chromatography with ultraviolet spectroscopy [3], high performance liquid chromatography with mass spectroscopy [4], electrochemioluminescense [5], infrared spectrometry [6], and electrochemical methods [7][8][9][10][11][12][13]. However, some of the above mentioned techniques have time-consuming steps and complexity which make them unsuitable for the accurate determination of chlorogenic acid.…”
Section: Introductionmentioning
confidence: 99%