2004
DOI: 10.1002/elan.200302825
|View full text |Cite
|
Sign up to set email alerts
|

Development of an Amperometric Biosensor for β‐N‐Oxalyl‐L‐α,β‐Diaminopropionic Acid (β‐ODAP)

Abstract: An amperometric method for the determination of the neurotoxic amino acid b-N-oxalyl-l-a,b-diaminopropionic acid (b-ODAP) using a screen printed carbon electrode (SPCE) is reported. The electrode material was bulkmodified with manganese dioxide and used as a detector in flow injection analysis (FIA). The enzyme glutamate oxidase (GlOx) was immobilized in a Nafion-film on the electrode surface. The performance of the biosensor was optimized using glutamate as an analyte. Optimum parameters were found as: operat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2006
2006
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 24 publications
0
7
0
Order By: Relevance
“…MnO 2 has also been used as the mediator for indirect glutamate determination, i.e. by detecting hydrogen peroxide [26]. Direct determination of the substrate, however, results in better stability of the enzyme and a more precise response of the sensor.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…MnO 2 has also been used as the mediator for indirect glutamate determination, i.e. by detecting hydrogen peroxide [26]. Direct determination of the substrate, however, results in better stability of the enzyme and a more precise response of the sensor.…”
Section: Introductionmentioning
confidence: 99%
“…For this purpose different mediators-electron-transfer complexes, e.g. Os complexes [12,13,[23][24][25] or tetrafulvalene-tetracyanoquinodimethane complex (TTF-TCNQ) [26,27]-were introduced for direct substrate oxidation:…”
Section: Introductionmentioning
confidence: 99%
“…Detection limits (as 3 value) for both analytes were 9.12 and 111.0 M with corresponding relative standard deviations of 3.3 and 4.5% respectively. The biosensor retained more than 73% of its activity after 40 days of on-line use [55].…”
Section: (B) Screen Printed Carbon Electrode Based Odap Biosensormentioning
confidence: 99%
“…Few amperometric ODAP biosensors have been reported in the literature [50][51][52][53][54][55][56], which act on the following principle: 2.6.1.1. Principle.…”
Section: Amperometric Odap Biosensorsmentioning
confidence: 99%
“…However, all of these methods suffered from glutamate interference. Either liquid chromatography (LC) 19,20 or an enzymatic method using glutamate decarboxylase 21 were employed to remove glutmate interference but it was time-consuming, expensive and complicated due to the enzyme/protein. Moreover, most of these methods did not satisfy the requirements for a simple, fast, accurate and specic method.…”
Section: Introductionmentioning
confidence: 99%