2020
DOI: 10.1007/s12161-020-01861-w
|View full text |Cite
|
Sign up to set email alerts
|

Development of an Alkaline Method for the Determination of Cu, Mo, and Zn in Beef Samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 22 publications
0
5
0
1
Order By: Relevance
“…Results obtained with a conventional introduction system after MAD with HNO 3 and H 2 O 2 were presented, and a visual inspection suggests that they were not significantly different from those obtained by alkali digestion and ETV introduction. A similar protocol was followed 44 for the determination of Cu, Mo, and Zn in beef. To 0.25 g sample were added 5.0 mL of H 2 O and 1.5 mL 25% (w/w) TMAH followed by heating at 85 °C for 60 min, cooling and centrifuging.…”
Section: Sample Collection and Preparationmentioning
confidence: 99%
“…Results obtained with a conventional introduction system after MAD with HNO 3 and H 2 O 2 were presented, and a visual inspection suggests that they were not significantly different from those obtained by alkali digestion and ETV introduction. A similar protocol was followed 44 for the determination of Cu, Mo, and Zn in beef. To 0.25 g sample were added 5.0 mL of H 2 O and 1.5 mL 25% (w/w) TMAH followed by heating at 85 °C for 60 min, cooling and centrifuging.…”
Section: Sample Collection and Preparationmentioning
confidence: 99%
“…Maximum pressure was set at 120 bar. After cooling down to 60 °C the chamber was depressurized, and digests were diluted with deionized water up to 10.0 mL [1].…”
Section: Sample Preparationmentioning
confidence: 99%
“…No gas mode means not using the collision cell, and He mode means when the collision cell is pressurized with Helium gas (99.999%, White Martins-Praxair, Sertãozinho, SP, Brazil). HMI mode implies the aerosol dilution with argon at a gas flow rate of 0.62 L min −1 and carrier gas flow rate of 0.40 L min −1 , thus 1.02 L min −1 of total flow rate [1]. Argon (99.999%, White Martins-Praxair, Sertãozinho, SP, Brazil) was used in this equipment.…”
Section: Analytical Determinationsmentioning
confidence: 99%
See 1 more Smart Citation
“…Um reagente alcalino interessante e que foi utilizado é o hidróxido de tetrametilamômio (TMAH), o qual tem sido bastante utilizado para solubilização total ou parcial de diferentes amostras (Katrin et al, 2014;Aranha et al, 2016;Iaquinta et al, 2020). O TMAH promove a solubilização da amostra com consequente extração de elementos metálicos de matrizes contendo alto teor de proteína, como é o caso do queijo.…”
Section: Introductionunclassified