2011
DOI: 10.1007/s00216-010-4645-0
|View full text |Cite
|
Sign up to set email alerts
|

Development of amperometric magnetogenosensors coupled to asymmetric PCR for the specific detection of Streptococcus pneumoniae

Abstract: A disposable magnetogenosensor for the rapid, specific and sensitive detection of Streptococcus pneumoniae is reported. The developed procedure involves the use of streptavidin-modified magnetic beads, a specific biotinylated capture probe that hybridizes with a specific region of lytA, the gene encoding the pneumococcal major autolysin, and appropriate primers for asymmetric polymerase chain reaction (PCR) amplification. Capture probes and amplicons specific for S. pneumoniae were selected by a careful analys… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
18
0

Year Published

2011
2011
2018
2018

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 28 publications
(18 citation statements)
references
References 34 publications
0
18
0
Order By: Relevance
“…These results demonstrated the usefulness of the developed sensors as screening or alarm devices indicating the possible presence of coliforms, together with their applicability to drinking water quality assurance (no coliform bacteria per 100 mL of water). The same research group employed similar strategies in the development of DNA sensors for the detection of a characteristic 235-bp region of the gene coding for autolysin (LytA), a specific pneumococcus virulent factor [48]. The obtained results demonstrated the usefulness of the developed methodology for rapid, simple, specific, quantitative, and sensitive detection of aPCR amplicons with a detection limit of 1.1 nM.…”
Section: Mbs-based Electrochemical Dna Sensorsmentioning
confidence: 67%
See 2 more Smart Citations
“…These results demonstrated the usefulness of the developed sensors as screening or alarm devices indicating the possible presence of coliforms, together with their applicability to drinking water quality assurance (no coliform bacteria per 100 mL of water). The same research group employed similar strategies in the development of DNA sensors for the detection of a characteristic 235-bp region of the gene coding for autolysin (LytA), a specific pneumococcus virulent factor [48]. The obtained results demonstrated the usefulness of the developed methodology for rapid, simple, specific, quantitative, and sensitive detection of aPCR amplicons with a detection limit of 1.1 nM.…”
Section: Mbs-based Electrochemical Dna Sensorsmentioning
confidence: 67%
“…The amplified products obtained by daPCR from bacteria attached to specific capture antibody-modified MBs were detected similarly to that commented above using the electrochemical genosensor [48]. The developed methodology allowed an easy discrimination between only 100 cfu mL À1 S. pneumoniae cultures and high concentrations (~1.0 10 8 cfu mL…”
Section: Magnetoimmuno-pcr Approachesmentioning
confidence: 99%
See 1 more Smart Citation
“…A disposable amperometric MMPs-based DNA sensor coupled to asymmetric PCR (aPCR) was developed for the ultrasensitive determination of Streptococcus pneumoniae [47]. This approach was based on the selective hybridization of specific biotynilated capture DNA probe, complementary to a specific region of the pneumococcal lytA gene.…”
Section: Micromagnetic Particlesmentioning
confidence: 99%
“…Moreover, the content of target in real samples is low. To solve this difficulty, some detection methods based on polymerase chain reaction (PCR) derived techniques are developed, such as asymmetric PCR (Campuzano et al, 2011;Chen et al, 2013), magnetic separation (Stevenson et al, 2008;Ma et al, 2012), size separation on denaturing urea polyacrylamide gel electrophoresis (Marimuthu et al, 2012;Liang et al, 2015) and toehold-mediated DNA strand displacement (Khodakov et al, 2013). Although these methods can generate ssDNA or singlestranded toehold, there are also different weaknesses to limit their use in bioanalysis.…”
Section: Introductionmentioning
confidence: 98%