2015
DOI: 10.1016/j.chroma.2015.02.050
|View full text |Cite
|
Sign up to set email alerts
|

Development of amino acid derivatization reagents for liquid chromatography electrospray ionization mass spectrometric analysis and ionization efficiency measurements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
28
0
1

Year Published

2017
2017
2020
2020

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 30 publications
(30 citation statements)
references
References 27 publications
0
28
0
1
Order By: Relevance
“…One of the aims of this study was to find out whether the solvent and ion source are important factors when choosing the derivatization reagent. The information gained from the log IE measurements can help towards designing new derivatization reagents that provide higher ionization efficiency and lower detection limits . Structures of compounds with higher efficiencies can be used as the basis for new derivatization reagents.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…One of the aims of this study was to find out whether the solvent and ion source are important factors when choosing the derivatization reagent. The information gained from the log IE measurements can help towards designing new derivatization reagents that provide higher ionization efficiency and lower detection limits . Structures of compounds with higher efficiencies can be used as the basis for new derivatization reagents.…”
Section: Resultsmentioning
confidence: 99%
“…The MS ion optics parameters were optimized only by setting the Target Mass parameter. This approach has been previously validated for this instrument …”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The ionization efficiency (IE) of compound B 1 relative to compound B 2 is defined as the ratio of the respective response factors according to the followed equation as described in Rebane et al ., where R denotes the MS response and C denotes the concentration of the respective compounds, IE0.25em(),B1B2=R1C1R2C2 …”
Section: Resultsmentioning
confidence: 99%
“…Based on Lissamine rhodamine B sulfonyl chloride (LRSC) in our previous work, a new derivatization regent – 4'‐carbonyl chloride rosamine (CCR) – with a permanent charged moiety was designed and synthesized . According to the ion efficiency (IE) reported in the literature, the improvement of CCR was also discussed in this work.…”
mentioning
confidence: 99%