2019
DOI: 10.1007/s40192-019-00143-6
|View full text |Cite
|
Sign up to set email alerts
|

Development of a Versatile Mechanical Testing Device for In Situ Synchrotron Tomography and Diffraction Experiments

Abstract: A new mechanical stage to perform in situ 3D imaging using synchrotron X-ray tomography is presented. Pairing control and acquisition allows the running of high quality continuous mechanical tests to study damage and fracture in any kind of structural materials. The modular design make this device very versatile with the possibility to use many specimen geometries and load ranges up to 5 kN, and switch within minutes from tomography to X-ray diffraction configurations. Examples of successful experiments to stu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 9 publications
(3 citation statements)
references
References 25 publications
0
3
0
Order By: Relevance
“…The in situ test rig Bulky, designed at the Centre des Mate ´riaux, was used for the experiment [see Fig. 2(a) and the work by Pelerin et al (2019) for more details on the stress rig]. The anchoring system has been modified by integrating a quartz tube (8 mm in diameter and 1 mm thick) in order to comply with the DCT geometry, by allowing the detector to be brought as close as 5 mm to the rotation axis [Fig.…”
Section: In Situ Experimental Testingmentioning
confidence: 99%
“…The in situ test rig Bulky, designed at the Centre des Mate ´riaux, was used for the experiment [see Fig. 2(a) and the work by Pelerin et al (2019) for more details on the stress rig]. The anchoring system has been modified by integrating a quartz tube (8 mm in diameter and 1 mm thick) in order to comply with the DCT geometry, by allowing the detector to be brought as close as 5 mm to the rotation axis [Fig.…”
Section: In Situ Experimental Testingmentioning
confidence: 99%
“…So at present it is not clear which route is the best, and the answer certainly depends on the beamline. The two stress rigs, [37,38].…”
Section: Presentation Of Two Different Stress Rigsmentioning
confidence: 99%
“…Nanox and Bulky, used in the examples presented hereafter (see sections 3 and 4) are briefly shown here, more details can been found in dedicated papers [37,38].…”
Section: Presentation Of Two Different Stress Rigsmentioning
confidence: 99%