2008
DOI: 10.1109/jsen.2008.917482
|View full text |Cite
|
Sign up to set email alerts
|

Development of a Spectrophotometric Optode for the Determination of Hg(II)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 20 publications
(8 citation statements)
references
References 26 publications
0
8
0
Order By: Relevance
“…For the synthesis of the β-ketoiminato palladium(II) complex [Pd(OAc)L] (3), bis(benzoylacetone)diethylenetriamine (1, = LH) [36] was reacted with [Pd(OAc) 2 ] (2) in a 1:1 molar ratio in acetonitrile at ambient temperature for 16 h (eq. (1)).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…For the synthesis of the β-ketoiminato palladium(II) complex [Pd(OAc)L] (3), bis(benzoylacetone)diethylenetriamine (1, = LH) [36] was reacted with [Pd(OAc) 2 ] (2) in a 1:1 molar ratio in acetonitrile at ambient temperature for 16 h (eq. (1)).…”
Section: Resultsmentioning
confidence: 99%
“…All chemicals were purchased from commercial suppliers and were used without any further purification. Bis(benzoylacetone)diethylenetriamine (1) was synthesized according to a previously published method [36].…”
Section: Experimental Section 41 General Proceduresmentioning
confidence: 99%
“…This corresponds to saturation of the sensing reagent with analyte. A number of several recent studies have also used logarithm of analyte concentration in constructing calibration curves [31][32][33]. By extending the linear range using a semi-logarithmic scale (Figure 6), a whole range of concentrations between 0.3 and 40 ppm could be accurately measured.…”
Section: Analytical Characteristic Of the Sensormentioning
confidence: 99%
“…So far, many sensors for detecing Hg 2+ have been reported, such as electrochemical sensors 7,8 and fluorescent sensors, [9][10][11][12] however, the former cannot achieve remote monitoring and are not suitable for deep water while the latter have inherent drawbacks since they are influenced by light intensity fluctuations, temperature, and the concentration of indicator. To overcome the shortages mentioned, an optical fiber was adopted to prepare fiber-optic sensors because of its many advantages, including immunity to electromagnetic interference, remote control, small dimensions, light weight, and the potential for multiplexed arrays.…”
Section: Introductionmentioning
confidence: 99%