Development of a Simple and Fast Electrochemical Method to Evaluate Physical Stress in Athletes

Abstract: This work describes a simple and fast electrochemical method to evaluate the level of physical stress in athletes by monitoring total proteins in saliva. The proposed system is based on FIA with multiple pulse amperometric detection (FIA/MPA) using gold as the working electrode and 0.1 mol L À1 NaOH as the unique reagent. The proposed method is economical, fast (110 injections per hour) and allows the analysis of a small amount of saliva (~32 mL) with no sample treatment (just dilution). The results obtained b… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
0
1

Year Published

2012
2012
2020
2020

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 40 publications
(42 reference statements)
0
4
0
1
Order By: Relevance
“…Saliva samples were collected after informed consent was obtained from healthy people (after mouth rinse) using the Salivette device (Sarstedt AG & Co; Nümbrecht ‐ Germany). Salivette is designed as a synthetic swab which was inserted in the mouth and chews it for about two minutes to stimulate salivation [25] . After that, the swab with the absorbed saliva was placed in the Salivette tube for centrifugation at 5000 rpm for 2 minutes and volumes were collected in the range between 1 to 2 mL.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…Saliva samples were collected after informed consent was obtained from healthy people (after mouth rinse) using the Salivette device (Sarstedt AG & Co; Nümbrecht ‐ Germany). Salivette is designed as a synthetic swab which was inserted in the mouth and chews it for about two minutes to stimulate salivation [25] . After that, the swab with the absorbed saliva was placed in the Salivette tube for centrifugation at 5000 rpm for 2 minutes and volumes were collected in the range between 1 to 2 mL.…”
Section: Methodsmentioning
confidence: 99%
“…Salivette is designed as a synthetic swab which was inserted in the mouth and chews it for about two minutes to stimulate salivation. [25] After that, the swab with the absorbed saliva was placed in the Salivette tube for centrifugation at 5000 rpm for 2 minutes and volumes were collected in the range between 1 to 2 mL. The saliva samples were directly 2-fold diluted in supporting electrolyte (sample pretreatment step).…”
Section: Reagents and Samplesmentioning
confidence: 99%
See 2 more Smart Citations
“…Um dos problemas recorrentes do sistema BIA empregando eletrodos sólidos e detecção eletroquímica é o de contaminação/adsorção de componentes na superfície do eletrodo de trabalho. Esse problema pode ser contornado, em sistemas hidrodinâmicos, pela aplicação repetitiva e alternada de pulsos de potenciais de limpeza (detecção amperométrica pulsada) [63,[81][82][83]. Entretanto, a amperometria pulsada tem sido pouco utilizada como modo de detecção em sistemas BIA [49,84], talvez devido à maioria dos estudos empregando BIA com detecção amperométrica terem sido realizados com a solução no interior da célula no estado estacionário, sendo que a limpeza eletroquímica é mais eficaz com o meio (solução) em agitação.…”
Section: Análise Por Injeção Em Bateladaunclassified