Development of a sensitive and fast method for detection of catecholamines and metabolites by HRMS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
3
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 22 publications
1
3
0
Order By: Relevance
“…A capillary temperature, that helps the analytes to be emitted in solution form, was also tested and varied between 260, 280, 300, 320, 340, 360, and 380 • C. Capillary temperatures between 280-320 • C provided similar and satisfactory results with some differentiations for more acidic compounds which exhibited higher sensitivity in high capillary temperatures. This observation is in accordance with another published work [59]. There is no ideal capillary temperature that fits equally for all the analytes of interest, so 320 • C was selected as optimal.…”
Section: Mass Spectrometry-ltq Orbitrap Esi Conditionssupporting
confidence: 88%
“…A capillary temperature, that helps the analytes to be emitted in solution form, was also tested and varied between 260, 280, 300, 320, 340, 360, and 380 • C. Capillary temperatures between 280-320 • C provided similar and satisfactory results with some differentiations for more acidic compounds which exhibited higher sensitivity in high capillary temperatures. This observation is in accordance with another published work [59]. There is no ideal capillary temperature that fits equally for all the analytes of interest, so 320 • C was selected as optimal.…”
Section: Mass Spectrometry-ltq Orbitrap Esi Conditionssupporting
confidence: 88%
“…Still, Khamis et al [6] assessed linearity, precision, accuracy, dilution integrity, selectivity, carryover, and stability to validate a method for the absolute quantification of amino/ phonel metabolites. Therefore, many works are related to the biological, pharmaceutical and chemical areas [4][5][7][8][9][10][11][12]. However, we have not found a method validation for fatigue tests in kingpins, as proposed in the current study.…”
Section: Introductionmentioning
confidence: 79%
“…Several approaches may be used to validate test methods. Roiffé et al [4] analysed repeatability, intermediate accuracy, matrix interference, limit of quantification, linearity, carryover and robustness to validate new analytical method for the analysis of catecholamines and its biotransformation products.…”
Section: Introductionmentioning
confidence: 99%
“…The instrument parameters were set as follows: Spray voltages were 3500 V and the capillary and probe heater temperatures were set to 320 and 350°C, respectively. Sheath gas and aux gas flow rate were 50 and 10 (in arbitrary units), respectively, and the S-lens RF level was 60 ( Roiffé et al, 2019 ).…”
Section: Methodsmentioning
confidence: 99%