2016
DOI: 10.1039/c6ay00931j
|View full text |Cite
|
Sign up to set email alerts
|

Development of a sample preparation method for acrylamide determination in cocoa via silylation

Abstract: This paper reports rapid and simple sample preparation method development for acrylamide (AA) determination in cocoa powder through conversion to N, O-bis(trimethylsilyl)acrylamide. AA level was quantified in the relation to a acrylamide-d 3 internal standard using gas chromatography coupled with ion-trap mass spectrometry in the single ion monitoring mode (GC-SIM-MS).Analytical procedure consisted of the extraction with organic solvent (acetonitrile with/without hexane addition), extract purification by dispe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
10
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
1
1

Relationship

2
6

Authors

Journals

citations
Cited by 10 publications
(11 citation statements)
references
References 19 publications
(32 reference statements)
1
10
0
Order By: Relevance
“…Three sub-samples of this homogenized sample were then used for AA determination. The samples were prepared using previously described methods, with a few modifications [13,14]. The analytical protocol used in this study was previously optimised and validated in-house [15].…”
Section: Methodsmentioning
confidence: 99%
“…Three sub-samples of this homogenized sample were then used for AA determination. The samples were prepared using previously described methods, with a few modifications [13,14]. The analytical protocol used in this study was previously optimised and validated in-house [15].…”
Section: Methodsmentioning
confidence: 99%
“…The sample extraction, clean-up, analysis and the solutions of calibration standards for all analytes were prepared according to our previous reports [19,20].…”
Section: Simultaneous Sample Preparation Methods For Pahs 3-mcpd and mentioning
confidence: 99%
“…It can be a new concept in view of its quickness, easiness, cheapness, effectiveness, ruggedness and safeness. As yet, this approach has shown its usefulness in the analysis of PAHs, 3-MCPD and AA in food [18][19][20]. However, to our best knowledge, the possibility of QuEChERS application for simultaneous sample preparation in the PAHs, 3-MCPD and AA analysis has still remained unexplored.…”
Section: Introductionmentioning
confidence: 99%
“…In addition, GC–MS quantification is hampered by the lack of unique ion of acrylamide (which is a low-mass monomer) and matrix interference. Therefore, liquid chromatography–tandem MS (LC–MS/MS) is the most utilized method for the determination of acrylamide not only in chocolate but also in other complex matrices. An alternative solution, with good sensitivity and selectivity, is the derivatization of acrylamide via bromination or silylation and conducting analysis by GC–MS or GC–MS/MS. …”
Section: Introductionmentioning
confidence: 99%