2020
DOI: 10.1016/j.foodchem.2019.125652
|View full text |Cite
|
Sign up to set email alerts
|

Development of a reproducible method of analysis of iron, zinc and phosphorus in vegetables digests by SEC-ICP-MS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 27 publications
(25 reference statements)
0
4
0
Order By: Relevance
“…Preparation of samples followed the method of Dell'Aquila et al . 52 but with some modifications. The samples were dissolved in a diluent solution of 1% nitric acid (HNO 3 ), which contained Sc, Ge, Rh and In as the internal standard aiming to represent the full mass range.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Preparation of samples followed the method of Dell'Aquila et al . 52 but with some modifications. The samples were dissolved in a diluent solution of 1% nitric acid (HNO 3 ), which contained Sc, Ge, Rh and In as the internal standard aiming to represent the full mass range.…”
Section: Methodsmentioning
confidence: 99%
“…In order to explore the connection between NS and changes in the relative metal elements, a NexION 1000 series ICP-MS (PerkinElmer, Inc., USA) was used for the detection of metal elements. Preparation of samples followed the method of Dell'Aquila et al 52 but with some modifications. The samples were dissolved in a diluent solution of 1% nitric acid (HNO 3 ), which contained Sc, Ge, Rh and In as the internal standard aiming to represent the full mass range.…”
Section: Analysis Of Metal Element Profiles In Serum and Urine Based ...mentioning
confidence: 99%
“…Separation of samples was performed via size-exclusion chromatography [20] using a high-performance liquid chromatography (HPLC) (PerkinElmer LC 200 Series HS, Seer Green, Bucks, UK), a Flexar ultraviolet/visible (UV/VIS) detector operating at 280 nm and a high-pressure peristaltic pump equipped of PEEK tubing (0.17 mm id) and operating at a flow rate of 0.6 mL min −1 . Detection and quantification of elements were made using Chromera software (PerkinElmer v. 4.1.0).…”
Section: Methods Detailsmentioning
confidence: 99%
“…There are many complex samples matrix have been successfully analysed using ICP-MS such as honey [ 56 ], rice [ 57 ], cow, goat, buffalo, yak and camel milk [ 55 ], meat [ 51 ], spices and aromatic herbs [ 58 ], honeydew honey [ 52 ], dairy milk and plant based milk [ 54 ] and maize [ 59 ]. Hyphenation techniques such as size-exclusion chromatography (SEC-ICP-MS) for the separation of samples and analyse using ICP-MS has been applied for analysis of metals such as Fe, Zn and P in vegetables [ 53 ] ( Table 2 ).…”
Section: Mineralsmentioning
confidence: 99%