2007
DOI: 10.1016/j.agwat.2006.10.003
|View full text |Cite
|
Sign up to set email alerts
|

Development of a recording water flow meter using ultrasonic measurement of water levels in a slotted U-pipe

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
4
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 11 publications
0
4
0
Order By: Relevance
“…In 2005, six recording drainage meters of original design based on the ultrasonic measurement of water levels in a grooved U-pipe were installed to measure drain flow. The design, with three grooves of different width in a U-pipe, allowed precise flow measurements in the range 0-4 L s −1 , and the ultrasonic probe produced high temporal resolution records (Enamorado et al, 2007). The records of discharges enabled the construction of the drainage hydrograph for each drainage event and for the whole season.…”
Section: Soil and Water Analysismentioning
confidence: 99%
“…In 2005, six recording drainage meters of original design based on the ultrasonic measurement of water levels in a grooved U-pipe were installed to measure drain flow. The design, with three grooves of different width in a U-pipe, allowed precise flow measurements in the range 0-4 L s −1 , and the ultrasonic probe produced high temporal resolution records (Enamorado et al, 2007). The records of discharges enabled the construction of the drainage hydrograph for each drainage event and for the whole season.…”
Section: Soil and Water Analysismentioning
confidence: 99%
“…In this study, a small-sized pan-evaporimeter for dynamic analysis of evaporative demand in a greenhouse was developed by applying a supersonic sensor, which has often been used to measure the water level exactly (e.g., Enamorado et al, 2007). Furthermore, its performance and validity were examined by analyzing the characteristics of the pan evaporation rate on an hourly basis and its relation with the environmental elements, in addition, leaf transpiration rate in a greenhouse.…”
Section: Introductionmentioning
confidence: 99%
“…Such devices are known as ultrasonic flow meters. Enamorado et al [16] used an ultrasonic measurement of water levels in a slotted U-pipe for the measurement of drainage water flow. However, only water levels and not the flow velocity were measured by an ultrasonic sensor.…”
Section: Introductionmentioning
confidence: 99%