Development of a Novel Breast MRI Phantom for Quality Control

Abstract: The proposed breast MRI phantom can be used to obtain reproducible measurements and allows implementation of quality control measures for a modality that is being increasingly used.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
12
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 9 publications
(12 citation statements)
references
References 12 publications
0
12
0
Order By: Relevance
“…These design choices allowed the breast phantom to physically fit into MRI breast coils from two major vendors, which are representative of the commercially available breast coils. This is an improvement over a previous breast phantom, which fits in the coil of only one vendor (6). …”
Section: Discussionmentioning
confidence: 89%
See 3 more Smart Citations
“…These design choices allowed the breast phantom to physically fit into MRI breast coils from two major vendors, which are representative of the commercially available breast coils. This is an improvement over a previous breast phantom, which fits in the coil of only one vendor (6). …”
Section: Discussionmentioning
confidence: 89%
“…The breast phantom can be used to test fat suppression techniques; mimics T 1 and ADC values measured in vivo ; allows comparison testing of the left and right sides of the coil; and can be used to measure image distortion. Ideally, this breast phantom will be a tool to assess system-to-system variability, coil variability, longitudinal variation (4, 6), and variability across sequences, e.g., when evaluating imaging protocols for a clinical trial. This breast phantom allows users to optimize clinical imaging protocols without additional accrual of volunteers or patients.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…A breast phantom is a quality control device that can be used to quantify measurement variability due to system hardware, software, or imaging sequence. A breast phantom was introduced that is compatible with multiple coil styles, contains diffusion mimics for fat and healthy fibroglandular tissue, benign and malignant tumor tissue, and has an anatomically appropriate design, 9 distinguishing it from previous breast phantoms that were compatible with only one coil, 10 lacked diffusion mimics, 11 or lacked fat tissue mimics. 12 The goal of this study is to assess the ability of this breast phantom to serve as a quality control device for comparison of ADC data across scanner-coil-sequence combinations and repeated scanning (e.g., as would be required in a multisystem study or clinical trial).…”