Development of a new standard laboratory protocol for estimating the field attenuation of hearing protection devices. Part III. The validity of using subject-fit data

Abstract: The mandate of ASA Working Group S12/WG11 has been to develop ''laboratory and/or field procedure͑s͒ that yield useful estimates of field performance'' of hearing protection devices ͑HPDs͒. A real-ear attenuation at threshold procedure was selected, devised, tested via an interlaboratory study, and incorporated into a draft standard that was approved in 1997 ͓J. D. Royster et al., ''Development of a new standard laboratory protocol for estimating the field attenuation of hearing protection devices. Part I. Res… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
37
0

Year Published

2008
2008
2021
2021

Publication Types

Select...
6
4

Relationship

0
10

Authors

Journals

citations
Cited by 57 publications
(40 citation statements)
references
References 9 publications
(10 reference statements)
3
37
0
Order By: Relevance
“…However, our testing of the attenuation for these hearing protectors in the mannequin head and the range of attenuation achieved by subject fit testing show that more noise attenuation than the manufacturers' NRR may be possible with well-fitting hearing protectors. In contrast, subject fit test data also show that poorly fitting hearing protection provides attenuation much worse than the manufacturers' reported NRR [Berger et al 1996;Berger et al 1998;Franks et al 2000;Joseph et al 2007;Murphy et al 2011]. …”
Section: Analysis Of Hearing Protectorsmentioning
confidence: 75%
“…However, our testing of the attenuation for these hearing protectors in the mannequin head and the range of attenuation achieved by subject fit testing show that more noise attenuation than the manufacturers' NRR may be possible with well-fitting hearing protectors. In contrast, subject fit test data also show that poorly fitting hearing protection provides attenuation much worse than the manufacturers' reported NRR [Berger et al 1996;Berger et al 1998;Franks et al 2000;Joseph et al 2007;Murphy et al 2011]. …”
Section: Analysis Of Hearing Protectorsmentioning
confidence: 75%
“…These tests result in a so-called subject fit (SF) attenuation value. This method is proven and appears to give attenuations closer to real-world ones [31]. U.S. standards have subsequently been transposed into ISO/TS 4869-5:2006 [32].…”
Section: A Number Of Rules For Reaching Real-world Valuesmentioning
confidence: 99%
“…Several excellent review articles on this topic have been written. 13,14,15,16 Recently, a report on the measurement and rating of hearing protection devices was drafted for the EPA. 17 This report followed the convention of examining the attenuation ratings where the lower ratings represent what a certain percentage of users would achieve.…”
Section: Longitudinal Performancementioning
confidence: 99%