2021
DOI: 10.1016/j.micromeso.2021.110971
|View full text |Cite
|
Sign up to set email alerts
|

Development of a new simple spectroscopic determination coupled acid-motivated delivery system based on fluorescence turn-off MSNs@MPA-ZnS QDs for infection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(11 citation statements)
references
References 37 publications
0
11
0
Order By: Relevance
“…An EDC/NHS chemistry was selected to complete the modification, which is a mild method for surface modification under room temperature [ 44 ]. Usually, EDC/NHS chemistry is employed for protein combination through carboxyl–amidogen bonding [ 44 ]. In this work.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…An EDC/NHS chemistry was selected to complete the modification, which is a mild method for surface modification under room temperature [ 44 ]. Usually, EDC/NHS chemistry is employed for protein combination through carboxyl–amidogen bonding [ 44 ]. In this work.…”
Section: Methodsmentioning
confidence: 99%
“…Then, 1 mL ethylenediamine was added. Subsequently, pH value was adjusted to around 10.6 [ 44 ]. After incubation for 2 h under 37 °C, the solution was dialyzed to reach the modified CD (we named them NH 2 –CD) or the modified spCD (we named them NH 2 –spCD) suspension.…”
Section: Methodsmentioning
confidence: 99%
“…Given the absence of heavy metals in the structure, ZnS QDs have a long emission lifespan, improved water solubility, and low toxicity, which allows them to be widely used in biological systems. A pH- triggered QDs drug delivery system, described by Mandani et al , was proposed for the antimicrobial application of gentamicin 176 . In this study, MSNs (mesoporous silica nanoparticles) were chosen as gentamicin carriers, and MPA-ZnS QDs were used to encapsulate the nanopores and prevent the premature release of the drug.…”
Section: Quantum Dotsmentioning
confidence: 99%
“…However, strongly acidic media are not recommended as the X-ZnS QDs can be dissociated and the interaction between X ligands and ZnS QDs can be wrecked, leading to a decrease in the stability of QDs [12,28,49]. Therefore, pH = 5.6 has been chosen for the formation of the X-ZnS QDs/TC complex through hydrogen bond and the detection of TC by fluorescence quenching.…”
Section: Optimal Conditions For the Enhanced Fluorescence Detection O...mentioning
confidence: 99%