2015
DOI: 10.1016/j.measurement.2015.04.012
|View full text |Cite
|
Sign up to set email alerts
|

Development of a new electrochemical sensor for verapamil based on multi-walled carbon nanotube immobilized on glassy carbon electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
6
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 19 publications
(6 citation statements)
references
References 28 publications
0
6
0
Order By: Relevance
“…When the mixture of and leukocyte suspension was placed onto the surface of electrode, the shifts of the peak potentials, along with current peaks were both lower than blank potassium ferricyanide solution. The influence of current peak was reported to be associated with the concentration of the solution rather than the types of the solute [ 50 , 51 ]. Huan et al .…”
Section: Discussionmentioning
confidence: 99%
“…When the mixture of and leukocyte suspension was placed onto the surface of electrode, the shifts of the peak potentials, along with current peaks were both lower than blank potassium ferricyanide solution. The influence of current peak was reported to be associated with the concentration of the solution rather than the types of the solute [ 50 , 51 ]. Huan et al .…”
Section: Discussionmentioning
confidence: 99%
“…Indeed, the particular chemical, electrical, mechanical and structural properties of CNTs have led to the development of a variety of detection applications. CNTs promote charge transfer reactions and therefore improve the analytical characteristics of the sensor [20][21][22].…”
Section: Introductionmentioning
confidence: 99%
“…Some of these reports including fluorimetery, 6 spectrophotometry, 7,8 gas chromatography, [9][10][11][12] ion-chromatography, 13 HPLC, [14][15][16][17][18] HPLC/MS-MS, 19,20 LC-ESI-MS, 21 SPME-LC-ESI-MS, 22 MIP-LC-MS, 23 and electrochemical methods. 24 In spite of higher selectivity presented by above mentioned methods, most of them require sophisticated equipment and are costly, time consuming and also suffer from some disadvantages such as intricate and tedious operational procedure, and high material consumption which is quite inconvenient for for routine clinical applications. It is necessary for future individualized patient treatment to develop a simple, rapid and highly sensitive method for the monitoring of verapamil doses in the biological fluids.…”
Section: Introductionmentioning
confidence: 99%