2021
DOI: 10.1007/s00216-021-03683-z
|View full text |Cite
|
Sign up to set email alerts
|

Development of a multidimensional online method for the characterization and quantification of monoclonal antibodies using immobilized flow-through enzyme reactors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 27 publications
0
3
0
Order By: Relevance
“…Other advantages include full unattendance once the sequence starts and minimal new equipment purchase. When compared to other online type of approaches, , this technique offers a few important advantages, such as a retention of typical LC flow path that allows the use of the system for offline analysis, standard CDS usage with full compliance, and generally a simpler system that is easier to use, maintain, and troubleshoot. Additionally, it is possible to reduce the cost of consumables with the technique, as the trypsin column (Orachrom) and the custom-made desalting device are found to be extremely durable.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Other advantages include full unattendance once the sequence starts and minimal new equipment purchase. When compared to other online type of approaches, , this technique offers a few important advantages, such as a retention of typical LC flow path that allows the use of the system for offline analysis, standard CDS usage with full compliance, and generally a simpler system that is easier to use, maintain, and troubleshoot. Additionally, it is possible to reduce the cost of consumables with the technique, as the trypsin column (Orachrom) and the custom-made desalting device are found to be extremely durable.…”
Section: Discussionmentioning
confidence: 99%
“…Others have also automated peptide mapping with HPLC equipment; however, this typically involves adding significant complexity to the system that subsequently prevents it from being used as a standard UHPLC to perform nonautomated analysis. Many techniques are partially automated and require additional work before or after the digestion. Liu et al automated peptide mapping using a sequential injection device that was fully integrated into a PAT workflow . That approach has several advantages over the liquid handler approaches in that each sample is digested prior to analysis and the system is fully online.…”
Section: Introductionmentioning
confidence: 99%
“…During recent years, several authors have successfully demonstrated the application of two- or multi-dimensional LC coupled to MS (2D- or mD-LC–MS) methods for the qualitative and quantitative structural characterization of therapeutic antibodies and related protein formats. The mD-LC–MS approach combines sample preparation and multi-level analysis of antibody attributes within an automated continuously connected setup (online) and removes the need for manual sample preparation procedures and sample handling (offline). , …”
mentioning
confidence: 99%