2014
DOI: 10.1007/s00216-014-8387-2
|View full text |Cite
|
Sign up to set email alerts
|

Development of a multi-VOC reference material for quality assurance in materials emission testing

Abstract: Emission test chamber measurement is necessary to proof building materials as sources of volatile organic compounds (VOCs). The results of such measurements are used to evaluate materials and label them according to their potential to emit harmful substances, polluting indoor air. If only labelled materials were installed indoors, this would improve indoor air quality and prevent negative impacts on human health. Because of the complex testing procedure, reference materials for the quality assurance are mandat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
9
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 14 publications
(10 citation statements)
references
References 7 publications
0
9
0
Order By: Relevance
“…Sampling had to be conducted seven days after loading. The duration of seven days (in contrast to the normative testing of 28 days) was chosen for two reasons: On the one hand, the testing period for the participants should be as short as possible, and on the other hand, the emission profile at that time has a relatively consistent profile as shown by Nohr et al 7,8 …”
Section: Methodsmentioning
confidence: 99%
“…Sampling had to be conducted seven days after loading. The duration of seven days (in contrast to the normative testing of 28 days) was chosen for two reasons: On the one hand, the testing period for the participants should be as short as possible, and on the other hand, the emission profile at that time has a relatively consistent profile as shown by Nohr et al 7,8 …”
Section: Methodsmentioning
confidence: 99%
“…Air sampling was carried out on Tenax ® TA tubes followed by thermal desorption and GC/MS analysis on an Rxi‐5 mseconds column (RESTEK GmbH, Bad Homburg a.d.H., Germany, 60 m, 25 mm, 0.25 μm). Analyte separation, identification, and quantification were performed based on the procedure described by Nohr et al.…”
Section: Methodsmentioning
confidence: 99%
“…For the preparation of the RRT samples, 12 L of the lacquer system were prepared and mixed according to the scheme shown in Figure . Its composition was based on the findings published by Nohr et al. In summary, 20 g of the mixture was weighed into 500× large polystyrene (PS) Petri dishes (D 94 mm, surface area 69.4 cm²), while 2.5 g of the mixture was weighed into 40× small PS Petri dishes (D 34 mm, surface area 9.1 cm²).…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations