Development of a low cost gas diffusion device for ammonia detection in the vitreous humor and its preliminary application for estimation of the time since death

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
5
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 21 publications
0
5
0
Order By: Relevance
“…Ammonia evaporation is promoted by the basic pH solution; since the vial is a closed system, external disturbances to the liquid-gas interface are prevented. The device design resembled a previously described unit used for detecting ammonia in vitreous humor samples [39]. The method exploits a colorimetric reaction between molecular ammonia and the Nessler's reagent (Equation (1)).…”
Section: Fabrication Of the Gas Diffusion Devicementioning
confidence: 99%
“…Ammonia evaporation is promoted by the basic pH solution; since the vial is a closed system, external disturbances to the liquid-gas interface are prevented. The device design resembled a previously described unit used for detecting ammonia in vitreous humor samples [39]. The method exploits a colorimetric reaction between molecular ammonia and the Nessler's reagent (Equation (1)).…”
Section: Fabrication Of the Gas Diffusion Devicementioning
confidence: 99%
“…The drawback of this method is that it is susceptible to pH and other volatile amines. 29,30 To solve this pH interference problem, Flood et al proposed a new method for ion assay by ion-pair formation. Stromberg 31 introduced the NH 4 + selective ionophore nonactin for the NH 4 + assay; Jonah et al 32 used pyrazole to accomplish this, they have a common disadvantage, which is the interference of potassium ions.…”
Section: Introductionmentioning
confidence: 99%
“…Another common optical ammonia sensor is designed based on a pH indicator, where ammonia reacts with the pH indicator, and the pH indicator is then deprotonated, resulting in changes in absorption and fluorescence. The drawback of this method is that it is susceptible to pH and other volatile amines 29,30. To solve this pH interference problem, Flood et al…”
mentioning
confidence: 99%
“…Surprisingly, it was neglected by most of authors for quite obscure reasons, but probably related to well-known analytical problems in clinical chemistry and laboratory medicine. 1218 To the best of our knowledge, a single paper did appear in 1978 reporting an ammonium increase in the vitreous humour in correlation with the post mortem interval. In this article, a colorimetric method based on the Nessler’s reagent was used, without any separation step.…”
Section: Introductionmentioning
confidence: 99%
“…9 In addition, two more methodologies developed by Musile et al., a gas diffusion device and a microfluidic paper-based device, were recently developed in our research group. 18,19 The aim of both is the determination of NH 4 + in vitreous humour. Both of them are portable and provide in situ qualitative results which will need to be confirmed by CE.…”
Section: Introductionmentioning
confidence: 99%