Development of a high throughput 96-well plate sample preparation method for the determination of trileptal (oxcarbazepine) and its metabolites in human plasma

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
19
0

Year Published

2002
2002
2007
2007

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 28 publications
(20 citation statements)
references
References 6 publications
1
19
0
Order By: Relevance
“…Over the years, several chromatographic methods for OXC and racemic licarbazepine determination have been developed (Noirfalise and Collinge, 1983;Menge et al, 1987;Elyas et al, 1990;Rouan et al, 1994;Pienimaki et al, 1995;Souppart et al, 2001;Levert et al, 2002;Mandrioli et al, 2003;Franceschi and Furlanut, 2005;Lanckmans et al, 2006). However, only three chiral HPLC assays have been validated to determine S-and R-LC enantiomers, in which a very expensive column and mobile phase were employed (Flesch et al, 1992;Pichini et al, 1995;Volosov et al, 2000).…”
Section: Introductionmentioning
confidence: 99%
“…Over the years, several chromatographic methods for OXC and racemic licarbazepine determination have been developed (Noirfalise and Collinge, 1983;Menge et al, 1987;Elyas et al, 1990;Rouan et al, 1994;Pienimaki et al, 1995;Souppart et al, 2001;Levert et al, 2002;Mandrioli et al, 2003;Franceschi and Furlanut, 2005;Lanckmans et al, 2006). However, only three chiral HPLC assays have been validated to determine S-and R-LC enantiomers, in which a very expensive column and mobile phase were employed (Flesch et al, 1992;Pichini et al, 1995;Volosov et al, 2000).…”
Section: Introductionmentioning
confidence: 99%
“…By this method OXC and its metabolites are quantified accurately in less than 3 min and this aspect is very important for a routine therapeutic monitoring of these drugs. Both sample preparation and analytical run time of the OXC method described in this paper are faster and more simple than other chromatographic methods, using UV or MS as detectors, previously reported [10][11][12][13][14][15][16]. Moreover, because just 10 L are injected into LC/MS/MS system, this method allows us to work with small amounts of biological material, including that coming from experimental animals.…”
Section: Resultsmentioning
confidence: 94%
“…This method requires a simple preparative step with a total chromatographic run time of 3 min, so it is less time consuming compared with other LC/MS and LC/MS/MS methods reported in literature [10][11][12][13][14][15][16]19,20].…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Several analytical methods for the OXCBZ determina-tion in plasma or serum have been published and most of them are based on HPLC procedures (Kumps, 1984;Menge et al, 1987;Pienimaki et al, 1995;Levert et al, 2002aLevert et al, , 2002bSouppart et al, 2001) with UV detection. As OXCBZ, like carbamazepine, exhibits thermal instability, HPLC procedures are preferable over gas chromatography, which in addition requires elaborate sample pretreatment Paar, 1985, 1986).…”