2022
DOI: 10.3390/s22020531
|View full text |Cite
|
Sign up to set email alerts
|

Development of a High-Power Capacity Open Source Electrical Stimulation System to Enhance Research into FES-Assisted Devices: Validation of FES Cycling

Abstract: Since the first Cybathlon 2016, when twelve teams competed in the FES bike race, we have witnessed a global effort towards the development of stimulation and control strategies to improve FES-assisted devices, particularly for cycling, as a means to practice a recreational physical activity. As a result, a set of technical notes and research paved the way for many other studies and the potential behind FES-assisted cycling has been consolidated. However, engineering research needs instrumented devices to suppo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
2
1

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 38 publications
0
3
0
Order By: Relevance
“…The crank angle was evaluated through an incremental encoder (model LPD3806-360BM-G5-24C). The previously developed constant current topology electrical stimulation device, which is open source and was described in a previously published paper [ 9 ], was employed during the sessions. Firmware and software applications (Android app) for the algorithm presented in this paper are available as Supplementary Materials .…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The crank angle was evaluated through an incremental encoder (model LPD3806-360BM-G5-24C). The previously developed constant current topology electrical stimulation device, which is open source and was described in a previously published paper [ 9 ], was employed during the sessions. Firmware and software applications (Android app) for the algorithm presented in this paper are available as Supplementary Materials .…”
Section: Methodsmentioning
confidence: 99%
“…Finally, in order to track the desired pedaling cadence, the pulse amplitude of the different channels is modulated simultaneously by a PI controller over the instantaneous baseline stimulation pattern, which is constantly modified by the RL agent. The controller was described in previous work [ 9 ]. Thus, even though the agent is responsible for optimizing the stimulation pattern, the PI controller modulates the pulse amplitude for cadence tracking.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Although FES has been studied for several years, the signal's amplitude is still ambiguous, especially depending on the level of the patient's motion, which could not be complete due to the sickness condition [15,[30][31][32]. We considered a fundamental signal proposed as a reference signal satisfying a biphasic shape with a sawtooth shape of 30 Hz and a pulse width of 100 µs [15,[30][31][32]. At the same time, the trajectories of the simulated hand were obtained and used as the trajectory of reference.…”
Section: Fes Design Based On Digital Arbitrary Signal Generatormentioning
confidence: 99%