2022
DOI: 10.1007/s11095-022-03409-5
|View full text |Cite
|
Sign up to set email alerts
|

Development of a High-Dose Infant Air-Jet Dry Powder Inhaler (DPI) with Passive Cyclic Loading of the Formulation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2
1

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 45 publications
0
3
0
Order By: Relevance
“…A curved nasal prong was connected to the outlet of the GE and RE to direct the aerosol into the infant's nose. Further details on aerosol delivery to infants using the D2I approach are provided elsewhere ( Howe et al, 2022a , 2022b ).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…A curved nasal prong was connected to the outlet of the GE and RE to direct the aerosol into the infant's nose. Further details on aerosol delivery to infants using the D2I approach are provided elsewhere ( Howe et al, 2022a , 2022b ).…”
Section: Methodsmentioning
confidence: 99%
“…In this study the EIM modifications include use of interpolated fluctuation velocity and TKE, a lower limit on eddy lifetime, and a drift correction term ( Bocksell & Loth, 2001 , 2006 ; Mofakham & Ahmadi, 2020 ). The pharmaceutical aerosol system selected is an air-jet DPI ( Farkas et al, 2018a ; Farkas et al, 2018b ) for administering small-particle aerosols to infants ( Bass, Boc, et al, 2019 ; Howe et al, 2022a , 2022b ) via the nose-to-lung (N2L) route. To ensure that deposition mechanisms are accurately captured across a range of turbulence levels, additional benchmark systems are also considered, including a curved tube (deposition due to impaction enhanced by turbulent dispersion) and a vertical straight pipe (dispersion due purely to turbulent dispersion).…”
Section: Introductionmentioning
confidence: 99%
“…The percentage of albuterol EEG aerosol powder retained in the Rat AJ DPI at 1, 2, and 5 mg loading mass was determined using a high-performance liquid chromatography (HPLC) method adapted from Howe et al 23 In brief, the powder mass recovered from the device was dissolved in an appropriate volume of deionized water and analyzed by HPLC with a fluorescence detector (ex/em: 276/609 nm). Chromatographic separation was achieved using a Restek Allure PFP propyl column (5 μm, 60 Å, 150 × 2.1 mm) and a mobile phase composition of methanol and ammonium formate buffer (20 mM, pH 3.4 through addition of formic acid) in a ratio of 70:30, run at a flow rate of 0.4 mL/min.…”
Section: Small-animal Air-jet Dry Powder Insufflator (Rat Aj Dpi) The...mentioning
confidence: 99%