2021
DOI: 10.1021/acsestwater.1c00192
|View full text |Cite
|
Sign up to set email alerts
|

Development of a Heavy Metal Sensing Boat for Automatic Analysis in Natural Waters Utilizing Anodic Stripping Voltammetry

Abstract: Determination of the levels of heavy metal ions would support assessment of sources and pathways of water pollution. However, traditional spatial assessment by manual sampling and off-site detection in the laboratory is expensive and time-consuming and requires trained personnel. Aiming to fill the gap between on-site automatic approaches and laboratory techniques, we developed an autonomous sensing boat for on-site heavy metal detection using square-wave anodic stripping voltammetry. A fluidic sensing system … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 8 publications
(20 citation statements)
references
References 30 publications
0
12
0
Order By: Relevance
“…The main evaluation of the analytical performance of SPEs under laboratory conditions was already performed by the system developers and is reported in Yang et al ( 2021 ). In the context of this work, only the lifetime of the SPE involved in the integrated system and in use during the measuring campaigns was observed and documented.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The main evaluation of the analytical performance of SPEs under laboratory conditions was already performed by the system developers and is reported in Yang et al ( 2021 ). In the context of this work, only the lifetime of the SPE involved in the integrated system and in use during the measuring campaigns was observed and documented.…”
Section: Resultsmentioning
confidence: 99%
“…Consequently, we focused on Pb and Cu for the purpose of this study. Any further details concerning the set-up and the sensing performance of the HM microfluidic detection device can be found in the publication from Yang et al ( 2021 ).
Fig.
…”
Section: Methodsmentioning
confidence: 99%
“…SPCEs were fabricated the same as reported in our previous study. 27 For better quality control, all the SPCEs were cleaned in 0.05 M HCl and deionized water, and then pre-tested by SWASV. According to the obtained stripping curves (charge vs. potential), the SPCEs were selected only within the charge range of 2–4 mC.…”
Section: Methodsmentioning
confidence: 99%
“…an automatic in situ sensing boat navigating in large natural waters) that rely on their reusability more than precision could be compatible with the sensing system in this study. 27 Reproducibility is pivotal for mass production and thus, five GSH-SPCEs and five bare SPCEs were tested in the same mixed solutions of Cd 2+ , Pb 2+ , and Cu 2+ with the ratio of 1 : 1 : 1. All the obtained sensitivities are shown in Table S6.…”
Section: Synthesis and Characterizations Of The Gshmentioning
confidence: 99%
See 1 more Smart Citation