2018
DOI: 10.1016/j.supflu.2018.01.006
|View full text |Cite
|
Sign up to set email alerts
|

Development of a ferrocenyl-based MIP in supercritical carbon dioxide: Towards an electrochemical sensor for bisphenol A

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
17
0
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 43 publications
(19 citation statements)
references
References 44 publications
1
17
0
1
Order By: Relevance
“…During the supercritical dyeing process, Sc-CO 2 fluid near or slightly above its critical points (T c = 31.10 °C, P c = 7.38 MPa) produced substantial polymer swelling because of the dissolution of CO 2 in polymers [18]. Therefore, Sc-CO 2 was used as a non-toxic solvent in extractions [22,23], separations [24], chemical reactions [25], and various other applications [26,27]. Furthermore, CO 2 gives superior heat transfer properties for near-critical operation.…”
Section: Introductionmentioning
confidence: 99%
“…During the supercritical dyeing process, Sc-CO 2 fluid near or slightly above its critical points (T c = 31.10 °C, P c = 7.38 MPa) produced substantial polymer swelling because of the dissolution of CO 2 in polymers [18]. Therefore, Sc-CO 2 was used as a non-toxic solvent in extractions [22,23], separations [24], chemical reactions [25], and various other applications [26,27]. Furthermore, CO 2 gives superior heat transfer properties for near-critical operation.…”
Section: Introductionmentioning
confidence: 99%
“…Upon polymerization, all the peaks broaden due to the randomly crosslinked structure of QPPMS, compared to the crystal texture of APPBr. In addition, a new peak appears at around 1731 cm −1 , corresponding to the stretching vibration of ester group in EGDMA . 13 C‐NMR was utilized to further characterize the chemical structure of QPPMS [Figure (d)].…”
Section: Resultsmentioning
confidence: 99%
“…Commission regulation 2018/213 amended the previous UE regulation 10/2011 on the level of BPA in plastic food contact materials, reducing the specific migration limit from 0.6 to 0.05 mg BPA/kg [13]. Electrochemical sensors and liquid chromatography have increasingly been used in the last several years for the quantification of BPA in water and milk analysis [14,15]. High-performance liquid chromatography-tandem mass spectrometry methods can determine BPA, its major metabolite BPA-glucuronide, and eleven BPA analogues in human urine and blood serum [16,17].…”
Section: Introductionmentioning
confidence: 99%