2021
DOI: 10.3390/bios11060196
|View full text |Cite
|
Sign up to set email alerts
|

Development of a Diagnostic Biosensor Method of Hypersensitivity Pneumonitis towards a Point-of-Care Biosensor

Abstract: In spite of a current increasing trend in the development of miniaturized, standalone point-of-care (PoC) biosensing platforms in the literature, the actual implementation of such systems in the field is far from being a reality although deeply needed. In the particular case of the population screenings for local or regional diseases related to specific pathogens, the diagnosis of the presence of specific antibodies could drastically modify therapies and even the organization of public policies. The aim of thi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
8
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(9 citation statements)
references
References 38 publications
1
8
0
Order By: Relevance
“…The SARS-CoV-2 AbDM is based on the one presented by Fiordelisio et al (2021), where magnetic beads functionalized with an antigen react with a serum sample (with an unknown concentration of primary antibodies to be detected) and subsequently with a fluorescent conjugated secondary antibody to detect the emitted signal.…”
Section: Sars-cov-2 Antibody Detection Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…The SARS-CoV-2 AbDM is based on the one presented by Fiordelisio et al (2021), where magnetic beads functionalized with an antigen react with a serum sample (with an unknown concentration of primary antibodies to be detected) and subsequently with a fluorescent conjugated secondary antibody to detect the emitted signal.…”
Section: Sars-cov-2 Antibody Detection Methodsmentioning
confidence: 99%
“…For the plate detection reactions, incubation was performed at RT with shaking (250 rpm) for 2 h; finally, three washes were performed with B4 and resuspended in 50 µL of the same buffer. On the other hand, in the microfluidic chip, the incubation was 45 min at RT, with agitation by transverse magnet movement (TMM) (Fiordelisio et al, 2021). Subsequently, a wash was performed by transiting the beads through B4T and resuspending them in the same buffer for reading.…”
Section: Detection Reactionmentioning
confidence: 99%
See 2 more Smart Citations
“…and transducers. Many efforts are being made to develop this method, both in terms of improving the MNPs surface functionalization [4], [5], [6] [7] and the transducer [3], [4], [8], [9], [10], [11].…”
mentioning
confidence: 99%