Development of a Detection Device For Deteriorated ZnO Surge Arresters at AC Traction Substations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
2
1

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…To verify the validity of our method, we first calculated, on paper, the output characteristics obtained by applying the proposed method and the conventional method for the resistive leakage current simulated waveform f(t) of a deteriorated ZnO element (as discussed in Section 2). 8 Comparison results when the fundamental waves are each set to 100% are shown in Figure 11. In the proposed method, we found that the harmonic components of the output voltage around the third to fifteenth orders, which are the subject of this paper, were continuously amplified, and that the amplitudes thereof were greater than those of the fundamental wave.…”
Section: Extraction Of Resistive Leakage Current Using Rogowski Coilmentioning
confidence: 99%
See 1 more Smart Citation
“…To verify the validity of our method, we first calculated, on paper, the output characteristics obtained by applying the proposed method and the conventional method for the resistive leakage current simulated waveform f(t) of a deteriorated ZnO element (as discussed in Section 2). 8 Comparison results when the fundamental waves are each set to 100% are shown in Figure 11. In the proposed method, we found that the harmonic components of the output voltage around the third to fifteenth orders, which are the subject of this paper, were continuously amplified, and that the amplitudes thereof were greater than those of the fundamental wave.…”
Section: Extraction Of Resistive Leakage Current Using Rogowski Coilmentioning
confidence: 99%
“…We will demonstrate the validity of our device through bench testing and field testing. Additionally, we report on a threshold 8 that we discovered that serves as our measure for evaluating deterioration.…”
Section: Introductionmentioning
confidence: 99%
“…Lightning arrester failure is mainly caused by internal defects and external overvoltage. Several monitoring devices are developed for the arrester on‐line test [14–16]. Several methods exist in the surge protection industry for detecting and disconnecting the defective arresters [17–19].…”
Section: Introductionmentioning
confidence: 99%