Development of a chemiluminescent enzyme immunoassay for urinary 1-hydroxypyrene

Abstract: A chemiluminescent enzyme-immunoassay for urinary 1-hydroxypyrene has been developed and optimized. The enzymatic activity of horseradish peroxidase-labeled tracer was measured with an enhanced chemiluminescent system and the results were compared with those from conventional colorimetric detection. The method fulfilled all the requirements of accuracy and precision and the detection limit was 0.001 pmol/well, which enabled analysis in less than 1 microL urine. Subjects working in the center of Bologna who wer… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

3
2
0

Year Published

2003
2003
2015
2015

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 37 publications
(61 reference statements)
3
2
0
Order By: Relevance
“…The mean concentration reported for nonsmoking street policemen (0.07 µmol/mol creatinine) in this city is lower than that found for asphaltexposed paving workers and also within the mean usual concentration range (<0.10 µg/L). These values are very close to our results for Bordeaux street exposures, thus confirming previous findings [2,31,32,33] suggesting that 1-OHPy in urine cannot be used with confidence as a biomarker for nonoccupational PAH exposure. Moreover, these 1-OHPy contents are significantly lower than those 820 Fig.…”
Section: Comparison Of Solid-phase Fluorometric Analysis With Hplc Ansupporting
confidence: 94%
See 3 more Smart Citations
“…The mean concentration reported for nonsmoking street policemen (0.07 µmol/mol creatinine) in this city is lower than that found for asphaltexposed paving workers and also within the mean usual concentration range (<0.10 µg/L). These values are very close to our results for Bordeaux street exposures, thus confirming previous findings [2,31,32,33] suggesting that 1-OHPy in urine cannot be used with confidence as a biomarker for nonoccupational PAH exposure. Moreover, these 1-OHPy contents are significantly lower than those 820 Fig.…”
Section: Comparison Of Solid-phase Fluorometric Analysis With Hplc Ansupporting
confidence: 94%
“…The other samples (Urine 1 to 4) have been collected from anonymous volunteers at Bordeaux University Fig. 8 Urinary 1-OHPy concentrations (µmol/mol creatinine) determined at the end of the shift of a volunteer exposed in various urban sites with respect to morning concentrations, and comparison with data (marked with a star) reporting mean 1-OHPy concentrations among street policemen, industrial and road-exposed workers in the city of Budapest [15] reported for smokers (>0.13 µmol/mol creatinine) and are in accordance with other studies [2,34], which leads to the conclusion that urinary concentrations of PAH metabolites are influenced more by smoking habit than by exposure to urban atmospheric pollution.…”
Section: Comparison Of Solid-phase Fluorometric Analysis With Hplc Ansupporting
confidence: 86%
See 2 more Smart Citations
“…Some immunoassay techniques, such as enzyme-linked immunosorbent assay (ELISA) [2,3], fluorescence polarization immunoassay [4], chemiluminescent immunoassay [5], real-time immuno-polymerase chain reaction assay [6] and immunosensor [7], were developed for PAHs analysis. Several ELISA test kits for PAHs have been produced and are commercially available, among which RaPID and Ris C are the most widely studied and used [8].…”
Section: Introductionmentioning
confidence: 99%