Development of a 2-Channel Embedded Infrared Fiber-Optic Temperature Sensor Using Silver Halide Optical Fibers

Abstract: A 2-channel embedded infrared fiber-optic temperature sensor was fabricated using two identical silver halide optical fibers for accurate thermometry without complicated calibration processes. In this study, we measured the output voltages of signal and reference probes according to temperature variation over a temperature range from 25 to 225 °C. To decide the temperature of the water, the difference between the amounts of infrared radiation emitted from the two temperature sensing probes was measured. The re… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 8 publications
(8 citation statements)
references
References 17 publications
0
8
0
Order By: Relevance
“…Next, to measure IR signals induced by temperature, an embedded-type thermometer probe (CH 2) of a FOT was also constructed. As an IR fiber, we selected a silver halide optical fiber (PIR 900/1000, Art Photonics, Berlin, Germany) that can serve as a sensing element and an IR waveguide at the same time [ 17 , 18 , 19 , 20 , 21 , 22 ]. Diameters are 0.9 mm for the core only and 1 mm including the cladding.…”
Section: Materials and Experimental Setupmentioning
confidence: 99%
See 1 more Smart Citation
“…Next, to measure IR signals induced by temperature, an embedded-type thermometer probe (CH 2) of a FOT was also constructed. As an IR fiber, we selected a silver halide optical fiber (PIR 900/1000, Art Photonics, Berlin, Germany) that can serve as a sensing element and an IR waveguide at the same time [ 17 , 18 , 19 , 20 , 21 , 22 ]. Diameters are 0.9 mm for the core only and 1 mm including the cladding.…”
Section: Materials and Experimental Setupmentioning
confidence: 99%
“…Next, in the cases of FOTs, they normally use a silver halide optical fiber as an infrared optical fiber (IR fiber) to measure temperature by transmitting IR signals emitted from a heat source [ 17 , 18 , 19 , 20 , 21 , 22 ]. As a non-contact temperature sensor, those based on IR fibers have been fabricated to use in examination or treatment rooms where magnetic resonance imaging (MRI) or radiofrequency ablation (RFA) devices are installed [ 20 , 21 ].…”
Section: Introductionmentioning
confidence: 99%
“…The PIR fiber has a signal attenuation of 0.1-0.5 dB/m at a wavelength of 10.6 μm. (9,10) The CFOTS measures the peak wavelengths emitted at a certain water temperature and derives the temperature.…”
Section: Methodsmentioning
confidence: 99%
“…In recent years, the surface plasmon resonance (SPR)-based optical sensing of several quantities such as chemicals [1,2], temperature [3], pressure [4], force [5], environmental monitoring [6], optofluidic detection [7], food safety [8], and biological species [9,10], as illustrated in Figure 1 [11][12][13][14], has been proven to be advantageous. The optical fiber deployed in such sensors has replaced the traditional substrates for SPR sensors such as prisms, electrodes, etc.…”
Section: Introductionmentioning
confidence: 99%