Development of 2 alternative enzyme-linked immunosorbent assays for routine screening of glutamic acid decarboxylase autoantibodies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
14
0
2

Year Published

2011
2011
2022
2022

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 12 publications
(18 citation statements)
references
References 19 publications
2
14
0
2
Order By: Relevance
“…4. b). These results showed that ELISA had a sensitivity of 58.6%; and a prevalence of 42.5% (SDs from -1.18 to 12.25, median SDs = 0.99) ( Table 2), not near to those for RBA, but similar to data previously reported for this method 10,12 . When evaluated by FloCMIA protocol C, the prevalence of positive results for this population was 47.5% and the relative sensitivity obtained was 58.6% (median SDs = 2.375), a value that was lower than that for RBA.…”
Section: Integrated Resultssupporting
confidence: 89%
See 2 more Smart Citations
“…4. b). These results showed that ELISA had a sensitivity of 58.6%; and a prevalence of 42.5% (SDs from -1.18 to 12.25, median SDs = 0.99) ( Table 2), not near to those for RBA, but similar to data previously reported for this method 10,12 . When evaluated by FloCMIA protocol C, the prevalence of positive results for this population was 47.5% and the relative sensitivity obtained was 58.6% (median SDs = 2.375), a value that was lower than that for RBA.…”
Section: Integrated Resultssupporting
confidence: 89%
“…These results indicated that ELISA had a relative sensitivity of 69.6% for this sera collection (percentage of patients RBA positive that were ELISA positive) and 100% specificity when analysis of control human sera was performed (calculated as 100% minus the percentage of false positives). These data are similar to those reported previously 12 . The ELISA showed SDs ranging from 0.11 to 10.03, and a median SDs = 5.02 (Table 1).…”
Section: Discussionsupporting
confidence: 93%
See 1 more Smart Citation
“…Recientemente se ha diseñado un método ELISA para determinación conjunta de GAD e IA-2, parece ser que con buenos resultados. Obtienen un 85% de positivos con el ensayo combinado GAD-65/IA-2 25,26 .…”
Section: Discussionunclassified
“…The protocol employed was based on those previously described [6265]. White Polystyrene microplates (96 F Maxisorp white microwell, Thermoscientific, Rockford, IL, USA) were coated ON at 4 °C with 40.0 ng of purified TrxIA-2 ic per well, washed three times with PBS, blocked for 1.5 h with 200 μL of blocking solution, and washed five times.…”
Section: Methodsmentioning
confidence: 99%