2018
DOI: 10.1002/mp.13093
|View full text |Cite
|
Sign up to set email alerts
|

Development, commissioning, and evaluation of a new intensity modulated minibeam proton therapy system

Abstract: We developed, implemented, and tested a new IMMPT system. The initial results look promising in cases where treatments can benefit from additional dose sparing to neighboring sensitive structures.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
27
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 23 publications
(28 citation statements)
references
References 29 publications
0
27
0
Order By: Relevance
“…For this, a model of the PBS nozzle at ICPO as well as a new, optimised nozzle design were created and investigated with respect to their focussing limits. While other groups have recently explored the use of narrow proton beams (diameter ≥3 mm) to improve conventional PBS treatment 11 and proton beam radiosurgery 12 , this work is the first one to evaluate magnetically focussed proton minibeams for pMBRT at a clinical centre.…”
Section: The Current Implementation Of Pmbrt With Mechanical Collimatmentioning
confidence: 99%
“…For this, a model of the PBS nozzle at ICPO as well as a new, optimised nozzle design were created and investigated with respect to their focussing limits. While other groups have recently explored the use of narrow proton beams (diameter ≥3 mm) to improve conventional PBS treatment 11 and proton beam radiosurgery 12 , this work is the first one to evaluate magnetically focussed proton minibeams for pMBRT at a clinical centre.…”
Section: The Current Implementation Of Pmbrt With Mechanical Collimatmentioning
confidence: 99%
“…A recent report of a scanned proton minibeam delivery development stated that a commercial proton therapy system was specially modified to produce scanned minibeams without collimation. 77 The resulting spot sigma was reported to be 1.4 mm at 221 MeV at the isocenter and below 1 mm at proximal distances. Comparative treatment planning results between regular IMPT and minibeam IMPT indicated target conformity improvement for the representative small and large intracranial targets considered ( Fig.…”
Section: A2 Small Scanned Proton Beamsmentioning
confidence: 99%
“…A recent report of a scanned proton minibeam delivery development stated that a commercial proton therapy system was specially modified to produce scanned minibeams without collimation . The resulting spot sigma was reported to be 1.4 mm at 221 MeV at the isocenter and below 1 mm at proximal distances.…”
Section: New Horizons: Beam Delivery Systemsmentioning
confidence: 99%
See 2 more Smart Citations