Pharm Anal Acta 2019
DOI: 10.35248/2153-2435.19.10.611
|View full text |Cite
|
Sign up to set email alerts
|

Development and Validation of Robust Analytical Method to Determine Droplets Size Distribution of Nasal Spray Using Laser Diffraction Technique

Abstract: In the recent past, delivery of therapeutic agents through the nasal route becoming a very attractive proposition, especially when rapid absorption and effects are required. The droplets size of a nasal spray dosage form is important for both efficacy and toxicity. In this study, an attempt was made to develop and validate a method to measure the droplets size distribution in Fluticasone nasal spray using Malvern spray tech coupled with automatic actuation station at various angles. Devices were actuated at th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
2
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 17 publications
0
2
0
Order By: Relevance
“…Strategies such as particle engineering, optimization of droplet size, and innovative delivery devices must be employed to minimize the risk of pulmonary deposition. Particularly, to avoid potential undesired effects from the lower respiratory tract due to inhalation in lungs, droplet diameters after spraying should exceed 10 µm, producing only a low proportion of smaller droplets (<10 µm) [88]. Additionally, factors influencing mucociliary clearance, the presence of protective mucus barriers, and variations in nasal physiology among individuals further complicate the task [89].…”
Section: Disadvantages Of In Drug Deliverymentioning
confidence: 99%
“…Strategies such as particle engineering, optimization of droplet size, and innovative delivery devices must be employed to minimize the risk of pulmonary deposition. Particularly, to avoid potential undesired effects from the lower respiratory tract due to inhalation in lungs, droplet diameters after spraying should exceed 10 µm, producing only a low proportion of smaller droplets (<10 µm) [88]. Additionally, factors influencing mucociliary clearance, the presence of protective mucus barriers, and variations in nasal physiology among individuals further complicate the task [89].…”
Section: Disadvantages Of In Drug Deliverymentioning
confidence: 99%
“…However, the droplet size distribution plays an important role in the safety of administration and its prevention from entering the tracheo-bronchi system. Rao et al [1] have conducted analysis of nasal spray droplet size distribution and determined the effect of different actuation angle on the observations. The study revealed that velocity does not determine the droplet size though change in actuation angle did.…”
mentioning
confidence: 99%