2017
DOI: 10.22159/ijap.2017v9i6.21616
|View full text |Cite
|
Sign up to set email alerts
|

Development and Validation of HPLC-Dad Method for the Determination of Bisoprolol in Tablet Dosage Forms

Abstract: Objective: A rapid, simple and sensitive RP-HPLC method was developed and validated for the determination of bisoprolol fumarate in bulk and pharmaceutical dosage form. ABSTRACT Methods:Chromatographic separation was achieved within 2.5 min on ACQUITY Arc System, Waters Symmetry C18 column (3.9 mm i.d. X 150 mm, 5 μm particle sizes) using a mobile phase consisted of acetonitrile: phosphate buffer (25:75 v/v) in an isocratic mode at a flow rate of 1.4 ml/min. The pH of the mobile phase was adjusted to 7.0 with … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
19
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
7
2
1

Relationship

4
6

Authors

Journals

citations
Cited by 25 publications
(20 citation statements)
references
References 6 publications
0
19
0
Order By: Relevance
“…In the present study, optimization and critical evaluation of mobile phase composition (gradient), flow rate, and analytical column were important to obtain good resolution of peaks of interest from the endogenous components, which, in turn, affect reproducibility and sensitivity of the method [4][5][6]. The resolution of peaks was best achieved with Discovery C18, 50×2.…”
Section: Resultsmentioning
confidence: 98%
“…In the present study, optimization and critical evaluation of mobile phase composition (gradient), flow rate, and analytical column were important to obtain good resolution of peaks of interest from the endogenous components, which, in turn, affect reproducibility and sensitivity of the method [4][5][6]. The resolution of peaks was best achieved with Discovery C18, 50×2.…”
Section: Resultsmentioning
confidence: 98%
“…Our objеctivе of the chromatоgraphіc method develоpment wаs to achiеve a peak tailing factor <1.5, retention time in between 1 and 3 min, along with gооd resоlution. [9][10][11] Ascentis express columns, based on Fusеd-core pаrticle technоlogy, prоvide more than twice the speed and efficiency of traditiоnal cоlumns at half the backpressure of sub-2-µm columns. This objеctive was obtainеd using mobile phase consisting of methanol and 0.1% solution of trifluoroacetic acid (40/60, v/v).…”
Section: Discussionmentioning
confidence: 99%
“…Therefore, all the experiments were carried out on a C18 column (Zorbax Eclipse ХDB-C18, 5 µm, 2.1 mm × 150 mm) by trying various mobile phase conditions systematically [4][5][6][7][8][9]. After the initial experiments, the optimum conditions were found to be the mobile phase of water:acetonitrile:trifluoroacetic acid (55:45:0.1 v/v/v) mixture pumped at 0.4 mL/min flow rate and 265 nm ultraviolet detection wavelength.…”
Section: Methods Optimizationmentioning
confidence: 99%