2019
DOI: 10.1016/j.chroma.2018.12.044
|View full text |Cite
|
Sign up to set email alerts
|

Development and validation of HILIC-UHPLC-ELSD methods for determination of sugar alcohols stereoisomers and its application for bioconversion processes of crude glycerin

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
4
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 31 publications
1
4
0
Order By: Relevance
“…The equations of each regression curve and coefficients of determination (R 2 ) are shown in Table 3 . A quadratic regression model was found to be more applicable than a linear regression model for GE species by showing better coefficients of determination, consistent with the known fact that the ELSD response was not linear [ 23 , 26 ]. The coefficients of determination were >0.9999 for all GE species, attesting that the method was reliable for GE quantitation ( Table 3 ).…”
Section: Resultssupporting
confidence: 66%
“…The equations of each regression curve and coefficients of determination (R 2 ) are shown in Table 3 . A quadratic regression model was found to be more applicable than a linear regression model for GE species by showing better coefficients of determination, consistent with the known fact that the ELSD response was not linear [ 23 , 26 ]. The coefficients of determination were >0.9999 for all GE species, attesting that the method was reliable for GE quantitation ( Table 3 ).…”
Section: Resultssupporting
confidence: 66%
“…Primary MR analyses were undertaken separately using single nucleotide polymorphisms (SNPs) associated with erythritol (P < 5 × 10 À8 ) in two of the largest GWAS studies in populations of European ancestry (NIHR and METSIM) (Table 1), which, based on linkage disequilibrium (LD), were partially overlapping (Supplementary Table 3) (13,14). Erythritol and threitol are isomers and cannot be distinguished by mass spectrometry unless separated by gas chromatography or liquid chromatography, with the latter dependent on the type of column used (15)(16)(17)(18). In the METSIM and NIHR GWAS cohorts, liquid chromatography with hydrophilic interaction liquid chromatography column was undertaken to separate erythritol, but GWAS of threitol was not performed (14,15,19).…”
Section: Cohortsmentioning
confidence: 99%
“…Erythritol and threitol are isomers and cannot be distinguished by mass spectrometry unless separated by gas chromatography or liquid chromatography, with the latter dependent on the type of column used (15)(16)(17)(18). In the METSIM and NIHR GWAS cohorts, liquid chromatography with hydrophilic interaction liquid chromatography column was undertaken to separate erythritol, but GWAS of threitol was not performed (14,15,19). We therefore undertook additional MR analyses using instruments from Twins UK/KORA in which erythritol and threitol were separated by gas chromatography prior to measurement with subsequent GWAS for both (18).…”
Section: Cohortsmentioning
confidence: 99%
“…Both amine and amide as well as traditional C18 stationary phases have been used to analyze carbohydrates and in particular simple sugars [18][19][20][21]. Therefore, an investigation into the analyses of these compounds on the silica hydride-based amide phase provides a useful insight for determining if this column can perform satisfactorily in this important application.…”
Section: Applications Of Silica Hydride Amide Stationary Phasementioning
confidence: 99%